Abicor Binzel TCS-FP Manual De Instrucciones página 39

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TCS-FP
Compressed air connection
Inner width
Nominal pressure
Working pressure
Quality of compressed air (ISO 8573-1:2010)
Tab. 4
Pneumatic distributor block
Operating voltage
Permitted range
Permissible residual ripple
Two 5/2 directional valves, internal
Actuation
Power consumption per valve
One 5/2 directional valve, external, for wire cutter
Actuation
Power consumption per valve
Tab. 5
Electrical connections
Pneumatic motor/nominal speed with oiled air
Air consumption
Container (anti-spatter fluid)
Air supply connection
Max. torque
Tab. 6
TCS-FP pneumatic motor
Injection unit
Operating pressure
Max. actuation time
Anti-spatter fluid consumption
Tab. 7
Injection unit
Cutting capacity at 6 bar
Solid wire
Cutting time
Tab. 8
Wire cutter
3.2 Abbreviations
TCS-FP
DAV
TSi
Tab. 9
Abbreviations and term definitions
Unit of measurement in drawings or diagrams
Tab. 10
Dimensions
BAL.0713.0 • 2019-02-11
3 Product description
G1/4"
ø
6
Min.
mm
6 bar
6 - 8 bar
Min. class 4
24 VDC/15 W
20...30 VDC
Vss < 10%
24 VDC
2.8 W
24 VDC
2.8 W
Approx. 650 rpm at 6 bar
Approx. 400 l/min.
1 l
Inner width 6 mm
8 Nm
1 liter bottle capacity
Max. 6 bar
4 s
Depends on the dosing
Up to 1.6 mm
1.0 seconds
Torch cleaning station
Wire cutter
Injection unit
Millimeter [mm]
EN - 9

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido