TCS-FP
LED Color
Status Description
9
Orange
On
Off
10
Orange
On
Off
11
Orange
On
Off
12
Orange
On
Off
13
Green
On
Off
14
Green
On
Off
15
Green
On
Off
16
Green
On
Off
Tab. 14
LED status module
7 Operation
NOTICE
• As the TCS-FP cleaning station is integrated into a welding system, the operating instructions of all welding components
must be observed during operation.
• Ensure that the TCS-FP is only ever operated when using the protective device supplied.
• Only qualified personnel are permitted to perform work on the device or system.
1 Switch on the robot control system.
2 Start the welding process.
3 Stop the welding process.
8 Decommissioning
NOTICE
• As the TCS-FP cleaning station is integrated into a welding system, the process for putting it out of operation depends
on the robot control system.
• When decommissioning the system, ensure that the procedures for switching off the welding components are observed.
1 Switch off the robot control.
BAL.0713.0 • 2019-02-11
"Y1 stroke cylinder up" output is active
"Y1 stroke cylinder up" output is not active
"Ext. Motor" output is active
"Ext. motor" output is not active
"OUT 5" output is active
"OUT 5" output is not active
"ERROR" output is active
"ERROR" output is not active
"S5 rotary check" input is active
"S5 rotary check" input is not active
"IN1" input is active
"IN1" input is not active
"IN2" input is active
"IN2" input is not active
"IN3" input is active
"IN3" input is not active
7 Operation