BROOM ROTATION OR REPLACEMENT
WARNING!
Shut off broom before entering this area. Do not work in this area
with engine running.
Every 50 hours, clean debris from inside the broom housing. Remove any string
wrapped around the broom, broom drive hub or idler hub. Check the bristle
length on the broom, replace the broom when the bristles are worn to a length
of 1-3/4 inches (4.4 cm). Rotate the broom every 100 hours.
To Rotate or Replace the Broom...
1
Open the Outer Access Door (13) and the Inner Access Door (15).
2
Remove the two Idler Arm Bolts (A) and pull the Idler Arm (B) away from
the broom. Slide the broom out of the broom housing.
3
Rotate the broom or install a new broom, following the instructions in
reverse order.
28 - FORM NO. 56041406 / Hydro-Retriever
ROTACIÓN O CAMBIO DE LA ESCOBA
Apague la escoba antes de entrar en esta zona. No trabaje en
esta zona con el motor funcionando.
Cada 50 horas, limpie las partículas que pueda haber dentro del alojamiento de
la escoba. Elimine las fibras que se enrollan a su alrededor, o alrededor del cubo
impulsor o del cubo de vacío. Compruebe la longitud de las cerdas de la escoba,
y cambie ésta cuando las cerdas estén gastadas y tengan una longitud de 4,4
cm. Rote las escobas cada 100 horas.
Para rotar o cambiar la escoba...
1
Abra la Puerta de acceso exterior (13) y la Puerta de acceso interior (15).
2
Retire los dos Pernos del brazo libre (A) y tire del Brazo libre (B) para que
salga de la escoba. Deslice la escoba fuera de su alojamiento.
3
Rote la escoba o instale una nueva, siguiendo las instrucciones en el
orden contrario.
™
2052
revised 3/00
ADVERTENCIA
A