Operation
Reading of error code E9
If E9 is read out, at least one error was made with
respect to the sequence of operations when performing
optimisation (System messages
— Abort the optimisation program by pressing the STOP
key and, if desired, start optimisation once again.
Fig. 5-49 OPTIMISATION "OP.12"
(4th measuring run of tyre/rim assembly)
Clamp the wheel on the balancer.
Rotate the wheel such that the valve is exactly
perpendicular to and above the main shaft.
Confi rm the valve position by pressing menu key
F1.
The OPTIMISATION "OP.13" screen (Fig. 5-50) is
displayed.
Fig. 5-50 OPTIMISATION "OP.13"
START is displayed on the screen.
Press the START key.
A measuring run is performed.
The
BALANCING screen
Finish weight minimisation / optimisation
Fig. 5-51 BALANCING
If the wheel running conditions are optimal, the
following codes can be displayed (Fig. 5-52):
H0 Wheel running conditions cannot be improved by
optimisation.
H1 Further optimisation not recommended but
feasible.
H2 Weight minimisation is recommended, optimisation
can achieve no further improvement.
F
7.1).
(Fig. 5-51) is displayed.