For more information on the factors that reduce and/or compromise suc-
tion lift and hence the pump's performance, see the troubleshooting sec-
tion in chap. 14.
Note that for temperatures and altitudes higher than those specified, the
motor's output is reduced and you will need to have a motor with greater
output or is necessary to reduced the request motor's performance. See
chap. 15.2 on the subject.
Make sure there is no water hammer or pressure peaks in the system
caused by fast-closing valves exceeding 1.5 times the pump's nominal pres-
sure. In the long run, they can cause damage to the actual pump.
Avoid operating the pump with the isolating valve on the delivery line closed
for any more than a few seconds.
EN
You should also avoid using the pump for continuous duty with a flow rate
below the minimum rate indicated on the rating plate as this may result in
the liquid being pumped overheating and in the unnecessary overloading of
pump or motor bearings.
11.4 STOPPING
a) Gradually interrupt water circulation in the delivery section to avoid
overpressure in the piping and pump caused by water hammering;
b) Cut off the power supply.

12. MAINTENANCE AND REPAIRS

Before commencing any maintenance work on the motor-
driven pump, turn off the power
The electric pump has no need of scheduled maintenance; however, you
should periodically check that it is running properly depending on the fluid
being pumped and the operating conditions; check in particular for abnor-
mal running noise and vibration.
Said checks may give you a rough idea of what preventive repairs are re-
quired, if any, instead of having to perform repairs following sudden prob-
lems.
The main and most common special maintenance operations are generally
as follows:
− replacement of mechanical seals
− replacement of grommets
− replacement of bearings
− replacement of capacitors. (where present)
Nonetheless, even these parts typically subject to wear may last a very long
time if the pump is used correctly.
When the pump remains inactive for a long period, it should be emptied
completely, removing the discharge and filling caps, washed carefully with
clean water then emptied. Do not leave water deposits inside. This opera-
tion must always be carried out whenever there is a chance of frost in order
to avoid the breakdown of the pump components.
When performing repair work, order original spare parts
from our sales and customer support network.
Non-original spare parts can damage the product and are
a hazard for persons and property.
12.1 REPLACEMENT OF SHAFT SEAL
13. DISPOSAL
When scrapping the product, observe local waste disposal regulations, and
do not leave any treated fluid inside it.
Most of our pumps do not contain hazardous polluting material.
The user is responsible for disposing of the equipment by taking it to a col-
lection and recycling facility authorized to dispose of electrical waste.
For further information on equipment collection points, contact your local
waste disposal authority or the store that you purchased the product from.
18
14. TROUBLESHOOTING
DISPLAYED FAULT
THE PUMP DOES
NOT WORK
The motor does not
turns
(*) If you encounter the same trouble again, call our Servicing De-
partment
THE PUMP DOES
NOT WORK
The motor turns
[-D-]
(**) Caution: mechanical seal could be damaged
CAUSE
SOLUTION
Check that the float
Float sticking
reaches the level ON
It reactivates
Thermal protection ac-
automatically
tivated (single phase)
(single phase only)
Check the terminal
Incorrect electrical
board and the
connection
electrical panel
Automatic switch
Reset the switch or
triggered or fuses
replace the fuses and
blown (*)
verify the cause
Check the electrical
No electricity
supply meter
Check the connection
Plug not inserted
to the power supply
Built-in thermal over-
Wait for built-in thermal
load protection device
overload protection
(if fitted) or thermal
device to reset or reset
cutout in control panel
thermal cutout in con-
tripped (*)
trol panel
Device protecting
Check water level and/
against dry running
or correct connection
tripped (*)
of system devices
Decrease in the line
Wait for voltage to
voltage
return to normal
Suction filter / hole
Pulire il filtro/foro
blocked
Release or clean the
Foot valve
valve and check that it
blocked (**)
works properly
Pump has not been
Fill (sect. 10)
filled (**)
Water level low (if no
protection system is
Restore water level
fitted) (**)
Prime the pump
Check any delivery
Pump not primed
non-return valves
Check the liquid level
Restrict the
Pressure too low
delivery gate

Publicidad