USB Logbook
Activate or deactivate the function for saving all error messages to a USB flash drive
AUTO / OFF / ON
Signal Input
-
Function: Ext Sig. / S0-Meter / OFF
for Ext Sig. function only:
-
Trigger type: Warning (warning shown on the display) / Ext. Stop (inverter is
switched off)
-
Connection type: N/C (normally closed) / N/O (normally open)
SMS/Relay
-
Event delay
For entering the delay time after which an SMS text message is sent or the relay
should switch
900–86400 seconds
-
Event counter:
For entering the number of events that lead to a signal:
10–255
Insulation Setting
-
Insulation warning: ON/OFF
-
Threshold warning: Enter a threshold value that would trigger a warning
-
Threshold error: Enter a threshold value that would trigger an error (not available in
all countries)
TOTAL Reset
Resets the max. and min. voltage values and the max. power of feeding in to zero in the
LOG menu.
Once values are reset, this action cannot be undone.
To reset the values to zero, press the "Enter" key.
"CONFIRM" is displayed.
Press the "Enter" key again.
The values are reset and the menu is displayed