Meter deviation/calibration
Meter calibration
Currency
Set the currency
Setting range
Feed-in tariff
Set the charge rate for the remuneration for energy fed into the grid
Setting range
Factory setting
CO2 factor
Set the CO2 factor for the energy fed into the grid
Fan
to check the fan functionality
Setting range
-
-
-
IMPORTANT! The inverter display does not indicate whether the fan is OK. The fan func-
tion can only be checked by listening and feeling.
Arc Detection
for checking arc detection/interruption
Setting range
Arc.det. Status
displays the current status of arc detection/interruption
Start Self-test
self-test to check whether the inverter interrupts grid power feed operation when an arc
is detected.
Test procedure:
1
2
3
4
The self-test starts. The arc detection/interruption function simulates an arc and sends
the corresponding signal to the inverter.
If the test is successful, the inverter disconnects from the grid and stops grid power feed
operation.
The message "Self-test completed and Start AFCI" is shown on the display.
5
3-digit, A-Z
2-digit, 3 decimal places
(depends on the country setup)
Test fan #1/test fan #2 (depending on the device)
Select the desired fan using the 'Up' and 'Down' keys
Pressing the 'Enter' key starts the test for the selected fan.
The fan runs until the menu is exited by pressing the 'Esc' key.
ArcDetector Status/Start Self-test
Select "Arc Detection" in the Setup menu
Press the "Enter" key
Use the up and down keys to select "Start Self-test"
Press the "Enter" key
Confirm the indication by pressing the "Enter" key
41