Setting range
English, German, French, Spanish, Italian, Dutch, Czech, Slo-
vakian, Hungarian, Polish, Turkish, Portuguese, Romanian
Night mode
Night mode controls the Fronius DATCOM and the inverter's display operation at night or
when insufficient DC voltage is available
Setting range
AUTO / ON / OFF
Factory setting
OFF
AUTO:
The Fronius DATCOM operation is maintained as long as a Fronius Data-
manager is connected to an active, uninterrupted Fronius Solar Net.
The inverter display is dark during the night and can be activated by pressing
any function key.
ON:
The Fronius DATCOM operation is always maintained. The inverter pro-
vides an uninterrupted 12 V DC voltage to supply Fronius Solar Net with
power. The display is always active.
IMPORTANT! When the Fronius DATCOM night mode is ON or on AUTO
with connected Fronius Solar Net components, the power consumption of
the inverter at night increases to around 7 W.
OFF:
No Fronius DATCOM operation at night, the inverter therefore does not re-
quire any power to supply electricity to the Fronius Solar Net at night.
The inverter display is deactivated at night and the Fronius Datamanager is
not available. To activate the Fronius Datamanager, switch the inverter on
the AC side off and back on and press any function key on the inverter's dis-
play within 90 seconds.
Contrast
Set the contrast on the inverter display
Setting range
0 - 10
Factory setting
5
Since contrast depends on temperature, it may be necessary to adjust the 'Contrast'
menu item when environmental conditions change.
Illumination
Preset the inverter display illumination
The 'Illumination' menu item only applies to the inverter display background illumination.
Setting range
AUTO / ON / OFF
Factory setting
AUTO
AUTO:
The inverter display illumination is activated by pressing any key. If no key
is pressed for 2 minutes, the display backlight goes out.
ON:
The inverter display illumination is permanently on when the inverter is ac-
tive.
OFF:
The inverter display illumination is permanently off.
31