Fronius Acctiva Easy MC 04 Manual De Instrucciones página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Troubleshooting
General faults
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Errors in test
After connecting the battery, there is nothing on the display during the open
mode
circuit voltage test
Cause:
Remedy:
Cause:
Remedy:
Errors during
Charging circuit switches off during charging
charging
Cause:
Remedy:
Safety cut-out
If the battery does not reach a predefined voltage level within a given period, the char-
ging circuit switches off. Please refer to „Technical data" for the length of time it takes
before the safety cut-out trips.
What to do in the case of a safety cut-out:
1. Move the charging circuit switch to the „O" position
2. Disconnect battery connection
3. Determine cause of trip
4. Rectify fault and restart charging if necessary
Cause:
Remedy:
Charger leads not connected to correct poles
Connect battery poles correctly
Battery open circuit/contact fault
Check charger leads, contacts and battery poles
Charger lead short circuit
Check charger leads, contacts and battery poles for short circuit
Battery is flat/in deep discharge
Recharge the deep-discharge battery
Charger leads not connected to correct poles
Connect battery poles correctly
High ambient temperature. Charging circuit overheating.
Allow to cool down. Charging will recommence automatically once the
charging circuit has cooled sufficiently
Battery too large
Restart charging
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acctiva easy mc 06

Tabla de contenido