5.3.1 Cleaning Instructions

When it is necessary to clean the braking module, follow the instructions below.

Ventilation system:

Disconnect the braking module power supply and wait at least 10 minutes.
Remove the dust from the cooling air inlet by using a soft brush or a flannel.
Remove the dust from the heatsink fins and from the fan blades by using
compressed air.
Electronic boards:
Disconnect the braking module power supply and wait at least 10 minutes.
Remove the dust from the electronic board by using an anti-static brush or an
ion air gun (Charges Burtes Ion Gun - reference A6030-6DESCO).
If necessary, remove the boards of the rectifier.
Always wear a ground strap.
32 | DBW03
Figure 5.1: Fan replacement