7.1 POWER DATA

Table 7.1: Technical specifications for the DBW03 braking module
Line
Model
(Vac)
DBW030380D3848 380-480 588-792
DBW030250D5069 500-690 816-1188
(1) Disregarding the power dissipated on the braking resistor.
Note:
(1) Steady state rated current in the following conditions:
- Temperature around the braking module: -10 °C (14 °F) to 45 °C (113 °F). The
braking module can operate at ambient temperatures up to 55 °C (131 °F) if the
output current is derated by 2 % for each degree Celsius above 45 ºC (113 °F).
- Relative air humidity: 5 % to 90 % non-condensing.
- Altitude: 1000 m (3.300 ft). Above 1000 m (3.300 ft) up to 4000 m (13.200 ft) the
output current must be derated by 1 % for each 100 m (330 ft) above 1000 m
(3.300 ft).
From 2000 m to 4000 m (6.600 ft to 13.200 ft) above sea level - maximum voltage
reduction (480 V for 380...480 V models) of 1.1 % for each 100 m (330 ft) above
2000 m (6.600 ft).
- Ambient with pollution degree 2 (according to EN50178 and UL508C).
(2) The specified losses are valid for rated operating conditions, that is, for rated
output current.

7.2 ELECTRONICS/GENERAL DATA

INPUTS (CDB)
OUTPUTS (CDB1 Board) RELAY
SAFETY
ENCLOSURE

7.2.1 Codes and Standards

SAFETY
STANDARDS
MECHANICAL
STANDARDS
34 | DBW03
Braking
Braking
Actuation
Overvoltage
Level
Fault (Vdc)
(Vdc)
800
1200
DIGITAL
1 insulated input and 1 thermostat input
2 relay outputs with NO/NC contacts, 240 Vac, 1 A
PROTECTION
Under/Overvoltage
Overtemperature on the heatsink and braking resistor
Overcurrent
Ground fault
IP00
UL 840 – Insulation coordination including clearances and creepage
distances for electrical equipment.
EN61800-5-1 – Safety requirements electrical, thermal and energy.
EN 50178 – Electronic equipment for use in power installations.
EN 60146 (IEC 146) – Semiconductor converters
EN 60529 – Degrees of protection provided by enclosures (IP code).
UL 50 – Enclosures for electrical equipment.
Rated
Effective
Minimum
Current
Power
Resistance
on the
(kW)
(Ω)
Module
(A)
301
1.8
380
297
2.6
250
Peak
Dissipated
Current
Power
(A)
(kW)
(1)
440
1.00
457
1.00