Fuse replacement and Reset Switches
The Swift EPS
has four fuses located at the rear of
b
the machine behind the removable panel. These
correspond to each of the grinder motors, the tamping
motor, and the electronic controls. Occasionally it
may be necessary to replace a fuse. When switching
fuses be sure to use only correctly rated replacement
fuses. Electronics = 1 ea. @ 125m amps (normal);
motor, grinder = 2 ea. @ 10 amps GDC; motor,
tamper = 1 ea. @ 1 amp GDC. On machines with
serialnumbers656andhigher,the10ampmotor
fuses are replaced with reset switches on the
exterorofthegrinder. The head of the switch will
protrude when it needs to be reset.
Note: See page 31-32 for fuse sizes and locations.
(1) Disconnect the Swift EPS
supply.
(2) Access the fuse area by removing the two
screws located at the lower part of the rear
panel door. Do not remove the ground wire
screw on the rear panel door.
(3) Pull the panel door down and away, then
unplug the ground wire, to expose the control
electronics.
La Marzocco International | USA • La Marzocco Technical Center s.r.l. | Italy
26
from its power
b
Pulldown
WARNING
HAZARDOUSVOLTAGE
DISCONNECTFROM
POWERSUPPLYBEFORE
SERVICING
Removescrews(2)
Pullout