Technical Specifications; Standard Accessories - baltur TBG 45 ME Manual De Instrucciones Para El Uso

Quemadores de gas de dos etapas progresivas / modulantes con leva electrónica
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

TECHNICAL SPECIFICATIONS

HEATING CAPACITY
OPERATION
NOx EMISSIONS
MOTOR
ABSORBED ELECTRICAL POWER*
line FUSE
IGNITION TRANSFORMER
VOLTAGE
PROTECTION RATING
FLAME DETECTOR
NOISE**
WEIGHT
Natural Gas (G 20)
FLOW RATE
PRESSURE
*)
Total absorption at start with ignition transformer on.
**) Noise levels measured in the laboratory of the manufacturer with burner running on test boiler, at maximum rated heating capacity.

STANDARD ACCESSORIES

BURNER COUPLING FLANGE
INSULATING GASKET
STUD BOLTS
HEXAGONAL NUTS
FLAT WASHERS
TECHNICAL AND FUNCTIONAL SPECIFICATIONS
Gas burner with low NOx and CO emissions in accordance with
"Class III" of the European standard EN676
Two-stage progressive output operation.
Noise levels measured in the laboratory of the manufacturer
with burner running on test boiler, at maximum rated heating
capacity.
Modulation ratio 1:4.
High fan output, low electrical absorption, low noise.
Combustion head with exhaust gas recirculation which allows
extremely low polluting emissions with particular attention to
nitric oxide (NOx).
TBG 45ME
MAX kW
MIN kW
Two-stage progressive / modulating burner
< 80 (Class III according to EN 676)
mg/kWh
0.50
kW
2730
r.p.m.
0.70
kW
A / 400 V
26 kV - 40 mA - 230/240 V - 50/60 Hz
1N ~ 230 V ± 10% - 50 Hz 3N ~ 400 V ±10% - 50 Hz
dBA
kg
45.3
MAX
m³n/h
10.1
MIN
m³n/h
MAX
mbar
TBG 45ME
No. 4 M 12
No. 4 M 12
No. 4 Ø 12
Maintenance facilitated by the fact that the mixing unit can be
removed without having to disassemble the burner from the
boiler.
Combustion air flow adjustment with closure of the shutter when
paused to prevent any heat dispersion to the flue.
Gas adjustment using the butterfly valve controlled by the step
servomotor electronically controlled.
Valves tightness control device compliant with European
standard EN676.
Equipped with 4 and 7 pole connectors, 1 flange and 1 insulating
gasket for fixing to the boiler.
Gas train exit possibility at the top or at the bottom.
4 / 22
0006081533_201403
TBG 60ME
450
600
100
120
0.75
2800
0.97
- -
4
IP 40
IONISATION PROBE
73
75
40
42
60.3
12.1
500
TBG 60ME
2
2
1
1
No. 4 M 12
No. 4 M 12
No. 4 Ø 12