USER U/I subme-
nu (user settings
for current and
voltage)
(continued)
Important! the conservation charging voltage is only available in Charge mode. Conser-
vation charging does not take place if conservation charging is set to OFF. However, if
the battery voltage drops below 12 V, charging starts.
Important! if charging does not end automatically after the set time has elapsed, the
safety cut-out is triggered and an error message appears on the display.
Set conservation charging voltage (setting range: Off / 12.0 - 15.5 V)
-
Press Start/Stop button
-
Display flashes. Adjust conservation charging voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Set safety cut-out (setting range: 2 h - 30 h)
-
Press Start/Stop button
-
Display flashes. Adjust time in 10 min intervals
-
Press Start/Stop button to confirm setting
Set maximum external power supply (Setting range: see Technical Data)
-
Press Start/Stop button
-
Adjust external power supply in 0.5 A steps
-
Press Start/Stop button to confirm setting
Set external power supply voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Adjust external power supply voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
20