2
6. HOW THE CLIENT MUST PREPARE FOR OPERATION
a) Getting the worksite ready.
• The client should provide a surface on which the machine will be installed as specified in the Operating conditions table.
b) Getting the power source ready.
• The electricity plant must comply with current national regulations in the country of installation and be properly earthed.
• Place an omnipolar isolator on the power feed line, upstream of the machine.
• The electrical wires should have the right size for the current used by the machine, so that the fall in overall voltage, at
full load, is less than 2%.
7. TECHNICAL DATA
Max. operating temp.
Relative humidity
Model
Tank dim.
FA121M
317 x 210
FA121
317 x 210
FA181M
380 x 210
FA181
380 x 210
FA182
380 x 210
FA251
400 x 260
FA252
400 x 260
FA381
452 x 260
FA382
452 x 260
PACKING DIMENSIONS
Model
FA121M
FA121
FA181M
FA181
FA182
FA251
FA252
FA381
FA382
DOUGH
GENERAL INFORMATION
Tank
Dough
Speed
capacity
KG
16 lt.
12 kg
16 lt.
12 kg
23 lt.
18 kg
23 lt.
18 kg
23 lt.
18 kg
32 lt.
25 kg
32 lt.
25 kg
41 lt.
38 kg
41 lt.
38 kg
width x depth x height
410 x 710 x 670
410 x 710 x 670
410 x 710 x 670
410 x 710 x 670
410 x 710 x 670
520 x 850 x 740
520 x 850 x 740
520 x 850 x 740
520 x 850 x 740
FA121M - FA121
FA181M - FA181 - FA182
FA251 - FA252 - FA381 - FA382
+40° C
10 ÷ 80 %
Motor power
1
0.55 kW
1
0.55 kW
1
0.75 kW
1
0.75 kW
2
0.55 kW / 0.37 kW
1
1.10 kW
2
1.10 kW / 0.75 kW
1
1.10 kW
2
1.10 kW / 0.75 kW
in mm
M3
0.19
0.19
0.19
0.19
0.19
0.32
0.32
0.32
0.32
2
Rated current
Electricity
supply
3.5 A
230 - 1 - 50 Hz.
1.61 A
400 - 3 - 50 Hz.
5.3 A
230 - 1 - 50 Hz.
1.94 A
400 - 3 - 50 Hz.
1.6A/1.3A - 4/6 P
400 - 3 - 50 Hz.
1400/900
2.64 A
400 - 3 - 50 Hz.
2.5A/2.2A - 4/6P
400 - 3 - 50 Hz.
1400/900
2.64 A
400 - 3 - 50 Hz.
2.5A/2.2A - 4/6P
400 - 3 - 50 Hz.
1400/900
0.0 42/2
Net
machine
weight
(empty)
60 kg
60 kg
69 kg
69 kg
69 kg
110 kg
110 kg
112 kg
112 kg