3. ROUTINE MAINTENANCE

Personnel carrying out the operations described below must have READ and UNDERSTOOD the safety
instructions in this handbook.
FOR THE DISPOSAL OF WORN PARTS see section 8.
4. ROUTINE MAINTENANCE CARRIED OUT BY THE MACHINE OPERATOR
FREQUENCY
Before every shift
At least once a week
At least once a week
At least once a
month
5. ROUTINE MAINTENANCE CARRIED OUT BY MAINTENANCE PERSONNEL
FREQUENCY
At least monthly
At least monthly
At least every 3
months
At least every 6
months
DOUGH
CHECK/ CONTROL
Check the work area
It should be clean and without
powder/dust
Check the proper functioning of:
Safety devices
the shut down function
Visual check for damage:
All machine plates are in place and
legible.
Visual check for damage:
Tool and tank
CHECK/ CONTROL
Check inside the casing and motor hous-
ings
Check the efficiency of:
mechanical couplings
Check the functioning of:
motor meters, control circuit relays.
Check the efficiency of:
the equipotential circuit and systems
of protection
FA121M - FA121
FA181M - FA181 - FA182
FA251 - FA252 - FA381 - FA382
MAINTENANCE
MODE and REQUIREMENTS
The worksite and all outer parts of the machine should
be clean; in addition, anything on the machine shall be
removed in order to guarantee proper and safe opera-
tion.
Visually inspect the safety devices and make sure they
are functioning, check interlocking and shut down
functions, make sure mobile devices are working prop-
erly.
If they are illegible, ask technical support for identical
replacements.
Tools wear down over time. If they are scored or
chipped, they should be replaced.

IMPORTANT

Only replace with original spare parts made by the
manufacturer.
MODE and REQUIREMENTS
All inner parts, the motor housings should be clean and
dry.
Remove any dust or powder with a vacuum cleaner.
Use suitable tools to tighten the terminal blocks,
screws, nuts, bolts and connections in general.
Set the tension of the transmission chain.
Visually check the relays and control circuits.
Use suitable instruments to measure the resistance
to earth of the plant and make sure it complies with
national regulations for the country where the machine
is installed.
6