Traverse - Pentax R-100 Serie Manual De Instrucciones

Estación total electrónica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

This function allows you the fixed, closed and open traverse calculations.
You can measure not only the corner points but also the sideshot points at the same time. When the
traverse is closed, the closing errors of coordinates are calculated and the corner points can be
adjusted. And the sideshot points from the corner point based on the adjusted each corner point's
coordinates are calculated.
One point of the traverse data uses the memory size of two or three coordinates data. And therefore
please confirm the remaining memory. The calculation type is the compass rule.
The traverse function can store the polar coordinates data and the rectangular coordinates data. And
it can send the polar data by DC1 or AUX format and rectangular data by DC1 or CSV format
respectively.
Back sight point
Known point
Corner point
Sideshot point
Closed traverse
8.4

Traverse

Fixed traverse
Start point
(Coordinate
Direction angle
s)
79
End point
(Coordinate
s)
Open traverse

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido