3.4. Cutting Nipples and Double Nipples
REMS Nippelfix (automatic inside clamping) or REMS Nippelspanner (inside
clamping) are used for cutting nipples. Make sure that the pipe ends are deburred
on the inside. Always push on the pipe sections as far as they will go.
To clamp the pipe section (with or without thread) with the REMS Nippelspanner,
the head of the nipple tightener is splayed by turning the spindle with a tool.
This may only be done with the pipe section fitted.
Makes sure that no shorter nipples than the standard allows are cut with the
REMS Nippelfix and the REMS Nippelspanner.
3.5. Cutting Left-handed Threads
Only REMS Magnum 2010, 2020, 4010 and 4020 are suitable for left-handed
threads. The die head in the tool carrier must be pinned with an M 10 × 40 screw
for cutting left-handed threads, otherwise this can lift and damage the start of
the thread. Set switch to position "R". Switch over the hose connections on the
coolant-lubricant pump or short circuit the coolant-lubricant pump. Alternatively,
use the changeover valve (Art. No. 342080) (accessory) which is fixed to the
machine. The flow direction of the coolant-lubricant pump is reversed with the
lever on the changeover valve (Fig. 9).
4. Maintenance
4.1. Maintenance
WARNING
Pull out the mains plug before carrying out maintenance or repair work!
5. Behaviour in the event of faults
5.1. Fault: Machine does not start.
Cause:
● Emergency stop button not released.
● Circuit breaker has tripped.
● Worn carbon brushes (Tornado 2000, Magnum 2000 / 3000 / 4000).
● Connecting lead and/or foot switch defective.
● Machine defective.
5.2. Fault: Machine does not pull through
Cause:
● REMS dies are blunt.
● Unsuitable thread-cutting material.
● Overloading of the electricity mains.
● Too small a cross-section of the extension lead.
● Poor contact at the connectors.
● Worn carbon brushes (Tornado 2000, Magnum 2000 / 3000 / 4000).
● Machine defective.
5.3. Fault: No or poor feeding of thread-cutting material at the die head.
Cause:
● Coolant-lubricant pump defective.
● Too little thread-cutting material in the oil tray.
● Screen in the suction nozzle soiled.
● Hoses on the coolant-lubricant pump switched.
● Hose end not pushed onto nipple.
5.4. Fault: The dies are open too wide despite the right scale setting.
Cause:
● The die head is not closed.
5.5. Fault: Die head does not open.
Cause:
● Thread was cut to the next biggest pipe diameter with the die head open.
● Length stop folded away.
5.6. Fault: No useful thread.
Cause:
● Dies are blunt.
● Dies are inserted incorrectly.
● No or poor feeding of thread-cutting material.
● Poor thread-cutting material.
● Feed movement of the tool carrier obstructed.
● Pipe material is unsuitable for thread cutting.
5.7. Fault: Pipe slips in chuck.
Cause:
● Dies heavily soiled.
● Pipes have thick plastic coating.
● Dies worn.
The gear of the REMS thread cutting machine is maintenance-free. The gear
runs in a closed oil bath and therefore needs no lubrication. Keep the clamping
and guide chucks, guide arms, tool carrier, die head, dies, pipe cutter and pipe
inside deburrer clean. Replace blunt REMS dies, cutting wheel, deburrer blade.
Empty and clean the oil tray from time to time (at least once a year).
Clean plastic parts (e.g. housing) only with the REMS CleanM machine cleaner
(Art. No. 140119) or a mild soap and a damp cloth. Do not use household
cleaners. These often contain chemicals which can damage the plastic parts.
Never use petrol, turpentine, thinner or similar products for cleaning.
Make sure that liquids never get inside the REMS thread cutting machine.
4.2. Inspection/Repair
WARNING
Pull out the mains plug before carrying out maintenance or repair work!
This work may only be performed by qualified personnel.
The motor of REMS Tornado 2000 / REMS Magnum 2000 / 3000 / 4000 has
carbon brushes. These are subject to wear and must therefore by checked and
changed by qualified specialists or an authorised REMS customer service
workshop from time to time.
Remedy:
● Release emergency stop button on foot switch.
● Press circuit breaker on foot switch.
● Have the carbon brushes changed by qualified personnel or an authorised
REMS customer service workshop.
● Have the connecting lead and/or foot switch inspected/repaired by an
authorised REMS customer service workshop.
● Have the machine checked/repaired by an authorised REMS customer service
workshop.
Remedy:
● Change dies.
● Use REMS thread-cutting materials REMS Spezial or REMS Sanitol.
● Use a suitable power source.
● Use cable cross-section of at least 2.5 mm².
● Check connectors, use another outlet if necessary.
● Have the carbon brushes changed by qualified personnel or an authorised
REMS customer service workshop.
● Have the machine checked/repaired by an authorised REMS customer service
workshop.
Remedy:
● Change coolant-lubricant pump.
● Refill thread-cutting material.
● Clean screen.
● Switch over hoses.
● Push hose end onto nipple.
Remedy:
● Close die head, see 3.1. Tools, changing the dies
Remedy:
● Close die head, see 3.1. Tools, changing the dies
● Set the length stop for closing and opening lever in the same direction.
Remedy:
● Change dies.
● Check numbering of dies to die holders, change dies if necessary.
● See 5.3.
● Use REMS thread-cutting materials.
● Loosen wing nut of tool carrier. Empty chip tray.
● Only use approved pipes.
Remedy:
● Clean dies.
● Use special dies.
● Change dies.