Information Messages; Leds - Astralpool 54068-MB Manual Tecnico

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
5.8.
5.8.

INFORMATION MESSAGES

INFORMATION MESSAGES
5.8.
5.8.
INFORMATION MESSAGES
INFORMATION MESSAGES
The Information Messages appear on the screen without the need to press any key.
These messages indicate what the system is doing at any given moment.
Heat Pump
OFF
Heat Pump
External Stop
Heat Pump
No Water Flow
Defrosting
Water T. XX.XºC
Verify Temp.
In
XXmXXs
Heating
Wait
XXmXXs
Heating ECO
Water T. XX.XºC
Temp OK
Water T. XX.XºC
Heat Pump
Very cold air
EOM Stop
Low performance
Stop Machine
Not available
Flow Always
5.9.
5.9.
5.9.
5.9.

LEDS

LEDS
LEDS
LEDS
Fixed Green
Flashing Green
Green Off
Red On
© ASTRALPOOL 2015 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT
The machine is stopped.
Does not heat because the user chooses not to.
The heat pump is stopped due to AUX entry.
The AUX entry can be used to program an external clock. (See
chapter 5.15. (page 24).
The water is not circulating.
The flowswitch signal indicates there is no water flow.
Defrost function is being performed.
Verifying temperature.
Waiting the set time delay, countdown displayed.
Countdown for the machine to begin heating.
Complying with fan or compressor delay time.
The machine is heating and reports the pool water temperature.
If the machine is operating in ECO or EOM mode, this is
displayed on the screen.
The water temperature is as programmed by the user (within
the set margin) and indicates water temperature.
The machine is stopped because the ambient temperature is
very low.
The machine is stopped because the ambient energy is very low,
according to EOM operation mode.
This screen indicates that to perform the requested operation
first the unit has to be stopped.
This screen indicates that the requested operation is not
available, for instance: Cool on a regular unit.
Indicates that at the time of performing a change Pool ↔ Spa the
flow was not stopped by the pump override system.
System is performing the normal heating process.
System is performing some necessary process to begin the normal
heating process (Defrost, delay times...).
No power, system off or an alarm has gone off.
System is off because an alarm has gone off
.
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Pag: 20