Before Use; Operation - Hilti PT 10 Manual De Instrucciones

Ocultar thumbs Ver también para PT 10:
Tabla de contenido

Publicidad

6. Before use

6.1 Setting up the tool 3
en
1. Check that the surface of the table or bench is flat
and that it stands level.
2. Place the concrete base on a sturdy table or bench
(if the PTA 30 is used, assemble and secure this
table first).
NOTE Version without PTA 30 table: Use an open-
end wrench to adjust the screw feet so that the
bubble of the bubble level on the tripod adapter is
inside the inner ring. Tighten all lock nuts on the
screw feet securely.
3. Position the flat surface of the concrete base so
that the hole for the tripod column lies beyond
the edge of the table.
NOTE Please observe the safety rules in the
section "Proper organization of the work area".
6.1.1 Fitting the tripod column 4 5 6
1. Fit the tripod column through the hole in the
concrete base from below and secure it with the
screws.
NOTE Please note that crank must be positioned
toward the front.
2. Fit the tripod head onto the tripod column.
3. Screw the PTA 70 tripod adapter onto the tripod
head. Rotate the tripod adapter until the designa-
tion "PTA 70" can be read from the front and then
use the hex. socket wrench supplied to tighten
the screw.

7. Operation

7.1 Mounting the laser tool on the tripod adapter
7.1.1 Mounting point lasers, rotating lasers
or multidirectional lasers on the tripod
adapter 9 10
1. Screw the PTA 70 tripod adapter onto the tripod
head.
16
Printed: 07.07.2013 | Doc-Nr: PUB / 5070500 / 000 / 00
6.1.2 Fitting the optical level 7
1. Unscrew the two wing screws and open the rear
cover on the concrete base.
2. Place the PTA 10 optical level on the raised part of
the concrete base and secure it with the adjusting
screw provided.
NOTE Take care to ensure that the filter unit is
directed toward the tripod head.
3. Close the rear cover on the concrete base and
tighten the two wing screws.
6.1.3 Electrical connections 8
1. Connect the cable from the PTA 10 optical level
to the connector on the rear of the concrete base.
2. Connect the supply cord to the rear of the concrete
base.
3. Plug the supply cord into the power outlet.
6.1.4 Setting up the PT 10 quick check device in
the horizontal plane 6 8
NOTE
The PT 10 must be set up in the horizontal plane
before use. First use the bubble level on the tripod
adapter as a reference and then the bubble level
incorporated in the optical level. The bubbles of both
levels must be centered (in the inner circle) before
the tool can be used for measuring. Calibrate the PT
10 quick check device before use.
2. Place the Hilti laser tool under test on the adapter
plate and switch it on.
3. Use the crank to adjust the height of the Hilti laser
tool so that the laser beam is aimed at the center
of the crosshairs in the middle of the filter disc.
7.1.2 Mounting the laser tool on the adapter
plate for the PP 10 and PP 11 pipe lasers
1. Screw the PPA 73 tripod adapter onto the tripod
head.