Motor Will Not Run
(See following page for steps)
Remove control box cover. Turn
sprayer ON. Observe green light
on control board.
No light
Once
Normal operation
Light on
Control board
Continuously
commanding
motor to run
Flashing
See Error Code
section for further
troubleshooting
40
See Step 1. Do
you have over
100 AC volts?
YES
See Step 3. Is the
proper reading
NO
present through the
thermal switch
wires?.
YES
See step 4. Does
NO
the motor run?
YES
Replace
potentiometer.
Pressure switch.
See Step 2. Do
NO
you have over
100 AC volts?
YES
Replace the
ON/OFF switch.
If motor is hot, let cool and
retest. If Step 4 still shows
incorrect resistance, replace
motor. The motor has
a defective thermal device.
Connect a test
transducer to the
board. Does the
motor run?
YES
Replace the
transducer
Cleanup / Nettoyage / Limpieza
Repair or
NO
replace
power cord.
NO
Replace the
control board.