Notice!
Only use plastic pressurized cups when processing cleaning agents.
Give preference to aluminium pressurized cups when processing pre-
servatives.
■ Unscrew the pressurized cup [1-4] / [1-7] / [1-13].
■ Fill material into the pressurized cup.
For version HRS-E
■ Place the material container in the pressurized cup.
■ Insert the riser [1-3] into the material container.
■ Screw on the pressurized cup.
■ Connect the corresponding wand at the quick coupling[1-15].
■ Connect the pressurized cup spray gun to the compressed air circuit at
the air connection [1-12]
■ Start the pressurized cup spray gun by pressing the trigger guard [1-11]
.
■ Clean the pressurized cup spray gun and wand after use (see chap-
ter 11.2).
9.2. Check the fan pattern
The fan pattern must be checked regularly together with the wand to
warrant a perfect fan pattern. This can be carried out by spraying onto
paper or another suitable surface. The fan pattern must show a uniform
distribution of material, surrounded by fine spray mist. If the fan pattern is
incorrect, clean the wand (see chapter 11.2) or adjust the input pressure
(see chapter 7).
9.3. Adjust the fan pattern (only in version with flow control)
The flow control nut [1-21] can be used to adjust the material flow and
thus also the fan pattern. The flow needs to be adjusted depending on
the viscosity of the material being used. For materials with high viscosity,
the flow control nut usually has to be unscrewed further than for materials
with low viscosity.
■ Turning the flow control nut [1-21] to the left increases the material flow.
■ Turning the flow control nut [1-21] to the right reduces the material flow.
■ Lock the corresponding setting with a counter nut [1-20].
9.4. Refill material
Remove the pressurized cup
■ Disconnect the compressed air supply to the pressurized cup spray
Operating Instructions SATA HRS
EN
119