Startup; Starting Up The System; Operating Notes - Balluff BTL7-P511-M Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL7-P511-M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99
BTL7-P511-M _ _ _ _ -A/B/CD/Y/Z(8)-NEX-S32/KA _ _
Micropulse Transducer - Rod Style
5

Startup

5.1

Starting up the system

Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and readjust the transducer, if
necessary.
Check for the correct values, especially after
replacing the transducer or after repair by the
manufacturer.
5.2

Operating notes

Check the function of the position measuring system
and all associated components on a regular basis.
Take the position measuring system out of operation
whenever there is a malfunction.
Secure the system against unauthorized use.
14
english
DANGER
Ignition protection
"nA" and "tb"

Publicidad

Tabla de contenido
loading

Tabla de contenido