7.5 Connecting the hand switch/controller
The following hand switches can be connected to the Start / Stop lifting column:
•
2-button hand switch (Start-Stop) to travel the lifting columns.
The hand switch is connected directly to the lifting column. The controller is installed in the lifting
column.
Assignment of the hand switch connection
View from front
3
1
4
5
2
Suitable DIN plug: MAS 50S
*
For a configuration with switched mode power supply, reversible overcurrent protection.
For a configuration used as a transformer: +40 V to +22 V depending on load, irreversible overcurrent protection. Ground is not c
The following external controllers can be externally connected to the lifting column:
Controller
MultiControl mono connection C
MultiControl duo
MultiControl quadro
Transformer controller 120 VA
connection C
MultiControl II
Compact-e-3
Ground*
Pin 1: +29 V / 200 mA*
Pin 4: drive in
Pin 2: drive out
Lifting column connection
DIN plug, round
DIN plug, round
DIN plug, round
DIN plug, round
Mini-Fit Jr. (rectangular)
Mini-Fit Jr. (rectangular)
Control example
Potential free contacts
Pin 2
Drive out
Pin 4
Drive in
Pin 1
+29 V*