100
AVENTICS | CL03/CL03-XL | R402000141–BDL–001–AE
Technical Data
Control
Valve option
pressure
[bar]
5/2 SR
2.5–10
5/2
2.5–10
5/3
2.5–10
2x3/2 NC
2.5–10
5/2 AR
2.5–10
2x3/2 NC/NO
2.5–10
2x3/2 NO/NC
2.5–10
2x3/2 NO
2.5–10
1)
Required control pressure curve 2x3/2-way directional control valves, with externally supplied pilots and the main
supply through port 1. See diagram below:
pc = control pressure in bar
pw = working pressure in bar
Working
pressure,
internal pilot
control [bar]
2.5–10
2.5–10
2.5–10
1)
2.5–10
2.5–10
1)
2.5–10
1)
2.5–10
1)
2.5–10
Working
Switching
pressure,
time
external pilot
t
/t
F
E
control [bar]
-1–10
16/29
13/40
-1–10
12/14
13/15
-1–10
14/15
14/15
-1–10
17/28
20/33
-1–10
17/26
19/30
-1–10
17/28
20/33
-1–10
17/28
-1–10
17/28
20/33
Flow rate [Nl/min]
Supply
[ms]
port 1
ports 3–5
825
970–1100
825
970–1100
750
950–1100
850
970–1100
825
970–1100
850
970–1100
850
850
970–1100
Supply
800
800
750
750
800
750
750
750