LEVELLING
Adjust the floor-mounted feet (A) to level the appli-
ance.

ELECTRICAL CONNECTION

Caution - warning
The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specified materials.
The appliance is supplied with operating voltage 230V/1N 50 Hz (230V/1N 60 Hz
available on request) (see attached wiring diagrams)
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply
as follows.
1 – If not already present, install an automatic circuit-
breaker (B), close to the appliance, with the following
characteristics.
– Thermal breaker device (to adjust see table on
page 4)
– Differential breaker set at 30 mA
– Class B or C (IEC 898)
2 – Undo the screws and remove the side panel (A).
3 – Connect the automatic circuit-breaker (B) to the
appliance's terminal board (C) and to the electrical
mains supply, in accordance with the electrical sys-
tem diagram provided at the back of the manual and
using a cable with the following characteristics.
– Weight:
than H05RN-F type (designation 245
IEC 57)
– Temperature of use:
70°C.
Important
When connecting, take care to connect the neu-
tral and earth lines.
4 – Replace the panel and retighten the screws when
the operation is complete.
English
A
C
- 55 -
IDM-39617701200.tif
B
A
IDM-39617701600.tif