Appendix
Setting level
Date
Time format
Date format
Main menu → Settings → PV input configuration →
PV1
PV2
Main menu → Settings → Energy management →
Mode ¹
Dyn. feed-in control ¹
¹ This menu item is not always displayed. Whether or not it is present depends on the unit type, the settings on the inverter, and the
firmware version.
² This menu item is always displayed. It is not possible to switch it off.
³ Can be reset to 0 via Main menu → Settings → Clear event log.
12
Values
Unit
Increment, select, explanation
Min.
Max.
31.12.
Setting Date
01.01.
2079
2015
Selection options:
Selection options:
The "PV input configuration" menu is only dis-
played on units with two PV inputs. You can se-
lect how the connected PV inputs work:
Independently or in parallel
Independently:
Both PV inputs (MPP tracker) work independently
of each other. Use when connecting two separ-
ately configured PV generator fields, e.g. east-
west roof mounting.
In parallel:
Both PV inputs (MPP tracker) work synchron-
ously. The MPP tracking determines the first PV
input. Use when setting up two PV generator
fields next to each other, e.g. if the input current
exceeds the maximum permitted value on the
data plate. The PV cables must be connected us-
ing Y-shaped manifolds.
The "PV input configuration" menu is only dis-
played on units with two PV inputs. You can se-
lect how the connected PV inputs work:
Independently or in parallel
Independently:
Both PV inputs (MPP tracker) work independently
of each other. Use when connecting two separ-
ately configured PV generator fields, e.g. east-
west roof mounting.
In parallel:
Both PV inputs (MPP tracker) work synchron-
ously. The MPP tracking determines the first PV
input. Use when setting up two PV generator
fields next to each other, e.g. if the input current
exceeds the maximum permitted value on the
data plate. The PV cables must be connected us-
ing Y-shaped manifolds.
Selection options:
0
W
This sub-menu item is only displayed if the Ener-
gymeter mode has been selected.
Makes it possible to set the power that is fed into
the network in 10 W increments
The Modbus energy meter is required to reduce
the feed-in of the PV inverter (e.g. 50% or 70% of
the generator power).
12h
24h
yyyy-mm-dd
dd.mm.yyyy
mm/dd/yyyy
off
Energymeter
Operating instructions VPV I 0020273427_02
Factory set-
ting
Independently
Independently