Setting level
PV-ready threshold
Main menu → Settings → Energy management → Configuration → Meter type →
Configuration
Main menu → Settings → Energy management → Configuration → Installation position →
Feed-in
¹ This menu item is not always displayed. Whether or not it is present depends on the unit type, the settings on the inverter, and the
firmware version.
² This menu item is always displayed. It is not possible to switch it off.
³ Can be reset to 0 via Main menu → Settings → Clear event log.
0020273427_02 VPV I Operating instructions
Values
Unit
Increment, select, explanation
Min.
Max.
300
5000
W
This sub-menu item is only displayed if the Ener-
gymeter mode has been selected.
The menu item allows for targeted supply of a
heat pump with excessive photovoltaic energy.
If the excess photovoltaic energy exceeds the
PV-Ready limit value, the wiring centre for feed-in
management sends a switch-on signal to the heat
pump.
The PV-ready threshold function can only be
used in combination with an energy meter and a
wiring centre for feed-in management.
When defining the PV-Ready limit value, all of
the electrical consumers that are present in the
building must always be taken into consideration.
If a heat pump is installed, a set value for the
PV Ready limit value, which lies above the heat
pump's electrical connected load by 200 W, may
be useful, for example.
This sub-menu item is only displayed if the Ener-
gymeter mode has been selected.
Makes it possible to set the Meter type.
The factory setting is the Schneider iEM3155,
which is recommended by the manufacturer.
Selection options:
As required in certain countries (e.g. Spain),
not all power has to be fed into the AC network
(100% own consumption). The inverter ensures
that AC power is not fed into the network de-
pending on whether the energy meter has been
installed in the feed-in path or in the consumption
path.
The actual limit can be reached by setting the
"Dyn. feed-in control" set value to 0. The Modbus
energy meter is required to do this.
B-Control EM300LR
Schneider iEM3155
Herholdt ECS3
Janitza ECS3
Herholdt ECS1
Janitza ECS1
B+G SDM120 Modbus
B+G SDM220 Modbus
B+G SDM230 Modbus
B+G SDM630 Modbus
Carlo Gavazzi EM24
KDK PRO380 Mod
ABB B23
Appendix
Factory set-
ting
1000
Schneider
iEM3155
Feed-in