Alternating current con-
nection
Dimensions when
unpacked (H x W x D)
Weight excluding pack-
aging
Display
Communication interfaces
Integrated direct current
load isolator
Cooling principle
IP rating
Overvoltage category
Direct current connection
Alternating current con-
nection
Dimensions when
unpacked (H x W x D)
Weight excluding pack-
aging
Display
Communication interfaces
Integrated direct current
load isolator
Cooling principle
0020273427_02 VPV I Installation and maintenance instructions
VPV I 1500/2 230V
–
Wieland RST25i3 plug
–
Cable diameter
10 to 14 mm²
–
Conductor cross-section
1.5 to 4 mm²
–
399 mm
–
657 mm
–
222 mm
11.7 kg
Graphic display 128 x 64 pixels
–
LAN: Ethernet port (RJ45)
–
COM 1: RS-485 (RJ45)
–
COM 2: Modbus (RJ45 con-
nection to the energy meter)
Yes, complies with DIN VDE
0100-712
–
Temperature-controlled fan
–
Speed variable
–
Internal (dustproof)
VPV I 3000/2 230V
IP 65
III (AC), II (DC)
–
Phoenix Contact SUNCLIX
(1 x pair)
–
Conductor cross-section
2.5 to 6 mm²
–
Wieland RST25i3 plug
–
Cable diameter
10 to 14 mm²
–
Conductor cross-section
1.5 to 4 mm²
–
399 mm
–
657 mm
–
222 mm
12.4 kg
Graphic display 128 x 64 pixels
–
LAN: Ethernet port (RJ45)
–
COM 1: RS-485 (RJ45)
–
COM 2: Modbus (RJ45 con-
nection to the energy meter)
Yes, complies with DIN VDE
0100-712
–
Temperature-controlled fan
–
Speed variable
–
Internal (dustproof)
VPV I 2000/2 230V
–
Wieland RST25i3 plug
–
Cable diameter
10 to 14 mm²
–
Conductor cross-section
1.5 to 4 mm²
–
399 mm
–
657 mm
–
222 mm
11.7 kg
Graphic display 128 x 64 pixels
–
LAN: Ethernet port (RJ45)
–
COM 1: RS-485 (RJ45)
–
COM 2: Modbus (RJ45 con-
nection to the energy meter)
Yes, complies with DIN VDE
0100-712
–
Temperature-controlled fan
–
Speed variable
–
Internal (dustproof)
VPV I 4000/2 230V
IP 65
III (AC), II (DC)
–
Phoenix Contact SUNCLIX
(2 x pair)
–
Conductor cross-section
2.5 to 6 mm²
–
Wieland RST25i3 plug
–
Cable diameter
10 to 14 mm²
–
Conductor cross-section
1.5 to 4 mm²
–
399 mm
–
657 mm
–
222 mm
14 kg
Graphic display 128 x 64 pixels
–
LAN: Ethernet port (RJ45)
–
COM 1: RS-485 (RJ45)
–
COM 2: Modbus (RJ45 con-
nection to the energy meter)
Yes, complies with DIN VDE
0100-712
–
Temperature-controlled fan
–
Speed variable
–
Internal (dustproof)
Appendix
VPV I 2500/2 230V
–
Wieland RST25i3 plug
–
Cable diameter
10 to 14 mm²
–
Conductor cross-section
1.5 to 4 mm²
–
399 mm
–
657 mm
–
222 mm
11.7 kg
Graphic display 128 x 64 pixels
–
LAN: Ethernet port (RJ45)
–
COM 1: RS-485 (RJ45)
–
COM 2: Modbus (RJ45 con-
nection to the energy meter)
Yes, complies with DIN VDE
0100-712
–
Temperature-controlled fan
–
Speed variable
–
Internal (dustproof)
51