Donning the Dräger FPS 7000 RP
Release the Dräger FPS 7000 RP from the standby position.
Full face
Pull the harness apart, then put your chin into the chin
mask
cup of the mask body (Figure C).
Pull the harness over your head and draw it
backwards.
Adjust the full face mask.
Pull the straps until evenly tightened; first the neck
straps, then the temple straps, finally the front strap
(Figure D).
Don the helmet, close the chin strap and check that
the helmet fits firmly on the head. Tighten the chin
strap if necessary.
Mask/
Don the helmet, leave the chin strap open.
helmet
Take hold of both mask/helmet adapters, then place
combina-
the upper edge of the mask body against your
tion
forehead.
Put your chin in the chin cup of the mask body.
Pull both mask/helmet adapters simultaneously
backwards and clip them into the helmet mask guide.
Adjust the mask body. The entire face seal must lie
flush against the head. Push the mask body under the
front strap or under the flame/heat barrier of the
helmet, if necessary.
Close the chin strap and check the tight fit of the
helmet, retighten the chin strap if necessary.
Have a second person check the fit of the mask/
helmet combination.
The mask/helmet adapters must be locked into the
mask guide.
Don the closed-circuit breathing apparatus and connect the
Dräger FPS 7000 RP to the closed-circuit breathing apparatus
Lock the plug-in coupling into the connector.
If a telephone device is used:
The position of the receiver must match the position of the ear.
Use a connector or prick pincers to connect the telephone device
to the telephone line and check if the telephone device works.
Checking for tight fit
Press both breathing hoses of the closed-circuit breathing
apparatus tightly together and inhale until negative pressure is
generated in the full face mask.
Hold your breath for a moment.
The negative pressure should be maintained. If not, retighten the
harness or adjust the position of the mask guide on the helmet
Repeat the test twice.
Make sure that the Dräger FPS 7000 RP is airtight before use!
If the Dräger FPS 7000 RP leaks, there is a danger of inhaling toxic
substances!
1)
:
1)
Follow the corresponding instructions for use.
(approved by Dekra Exam)
WARNING
1)
.
23