Cleaning and disinfection
Clean and disinfect the Dräger FPS 7000 RP after every use.
The mask body must be cleaned sufficiently thoroughly that no
residues of skin care products remain on the mask body. Otherwise
the elasticity in the sealing area can be lost and the mask will no
longer sit correctly.
Do not use solvents (e.g. acetone, alcohol) or cleaning agents
containing abrasive particles for cleaning and disinfection. Use only
the described procedures and the specified cleaning agents and
disinfectants. Other agents, doses and contact times may cause
damage to the product.
For information about suitable cleaning agents and
disinfectants and their specifications, refer to document
9100081 at www.draeger.com/IFU.
Remove accessories and the mouthpiece of the drinking valve
from the Dräger FPS 7000 RP and clean them separately.
If a Dräger MS-COM was mounted, put the protective cap on the
adapter for the Dräger MS-COM to avoid injuries.
If the Dräger FPS 7000 RP has a drinking valve, the valve must
be cleaned as described in "Cleaning and disinfecting the drinking
valve".
Place the wipers in the centre of the visor.
Prepare a cleaning solution consisting of water and a cleaning
agent.
Clean all parts using a soft cloth with cleaning solution.
Thoroughly rinse all parts under running water.
Prepare a disinfectant bath consisting of water and a disinfectant.
Put all parts to be disinfected in the disinfectant bath.
Thoroughly rinse all parts under running water.
26
WARNING
CAUTION
(approved by Dekra Exam)
Dry all parts in the air or in a drying cabinet (temperature: max.
60 °C). Do not expose to direct sunlight.
Mount the mouthpiece of the drinking valve and the accessories.
Mask/
Relubricate the sliding surfaces (ball joint, guide plate)
helmet
of the mask/helmet adapter with Voltalev
®
combina-
Molykote
111.
tion
Cleaning and disinfecting the drinking valve
Prepare the cleaning solution (completely dissolve 1 cleaning
tablet in 1 litre of drinking water) and fill it into the drinking
reservoir.
Replace the mouthpiece with the drain hose.
Connect the drinking reservoir to the outside of the drinking valve
with a hose.
Squeeze the cleaning solution from the drinking reservoir through
the drinking valve until a small amount of the solution emerges
from the drain hose.
Close the drain hose with a hose clip.
Allow the cleaning solution to act for 3 minutes.
Open the hose clip and squeeze approximately half of the
cleaning solution from the drinking reservoir through the drinking
valve.
Close the hose clip again and let the cleaning solution act for a
further 3 minutes.
Open the hose clip and squeeze the remaining cleaning solution
through the drinking valve.
Fill the drinking reservoir with clear drinking water.
Squeeze the water from the drinking reservoir through the
drinking valve.
Disconnect the drinking reservoir from the hose.
Using a compressed air pistol, blow oil-free compressed air into
the hose until the drinking valve is dry.
Remove the hose and the drain hose.
®
or