Technical data
�.1
KTS ���
Property
Main memory
Hard disk
Display
Battery
Operating voltage via
vehicle battery or power pack
Power consumption
Dimensions (L x W x H)
Weight (without
connection cables)
Operating temperature
�.2
Interface protocols
Control unit diagnostics via the interface protocols
ISO 9141-2, SAE J1850VPW, SAE J1850PWM and CAN
ISO 11898, ISO 15765-4 (OBD), OBD diagnostics accor-
ding to ISO 15031.
�.�
Multimeter specification
Measuring channel 1 (CH1)
Measuring channel 2 (CH2)
Input resistance > 900 kOhm.
�.�.1

DC measurement (CH1 and CH2)

Property
Measurement range
Precision
Resolution
�.�.2
AC and effective value measurement
(CH1 and CH2)
Property
Frequency range AC
Measurement range
Precision
Resolution
Robert Bosch GmbH
Value/range
1 GB
40 GB
TFT 12" color 800 x 600 pixel
Lithium-ionic, 7.2 V; 6 Ah
10 V – 30 V DC
approx. 40 W
300 x 400 x 125 mm
4200 g
0 °C – 40 °C
zero potential
potential based
Value/range
0 – 200 V, automatic ranging
± 0.75 % of reading,
plus
± 0.25 % of measurement range
100 µV –100 mV
(depending on mea-
surement range)
Value/range
5 Hz – 400 Hz
0 – 200 V, automatic ranging
± 3 % of reading,
plus
± 0.25 % of measurement range
100 µV – 100 mV
(depending on mea-
surement range)
Technical data | KTS ��� | �1
�.�.�

Resistance measurement (CH1)

Property
Measurement range
Precision
Resolution
�.�.4

Current measurement (CH1 and CH2)

Property
100 A clamp
600 A clamp
Shunt (only CH1)
General
input resistance
Diode test
�.4
Oscilloscope specification
Measuring channel 1 (CH1) zero potential/ potential based
Measuring channel 2 (CH2) potential based
Input resistance > 900 kOhm.
Property
Measurement range
Coupling
Signal source
Trigger mode
Trigger source
X deflection
From 1 second time deflection, the oscilloscope is
operated in roll mode.
Property
Y deflection at U
Y deflection at 600A cur-
rent clamp (1 mV/A)
Y deflection at 100A cur-
rent clamp (1 mV/A)
Y deflection at 600 mA shunt
�.5
Power pack
Property
Input voltage
Input frequency
Output voltage
Operating temperature
KTS ��� | �1
| �1
en
Value/range
0.1  – 1 M, automatic ranging
± 0.75 % of reading,
plus
± 0.25 % of measurement range
0.1  – 1000 
(depending on mea-
surement range)
Value/range
-100 A – 100 A
-600 A – 600 A
0 – 600 mA
1.5 M
Test voltage max. 2 V;
Test current < 2 mA
Value/range
0 – 200 V
DC, AC
U, I-clamp I-shunt
Standard, Auto, Auto-threshold
CH1, CH2
5 ms – 100 s
Value/range
200 mV – 200 V
200 A, 500 A, 600 A
20 A, 50 A, 100 A
200 mA, 500 mA, 600 mA
Value/Range
90 — 264 VAC
47 — 63 Hz
15 V
0 °C — 40 °C
|
1 689 989 017
2008-07-04