SubDrive/MonoDrive
s
CAUTION
!
For retrofit application (i.e. MonoDrive), make sure to check integrity of power and motor leads.
This requires measuring the insulation resistance with the suitable megohmmeter.
* See AIM Manual for specifications.
6. Feed the 230 VAC power leads through the larger
opening on the bottom left side of the SubDrive/
MonoDrive controller and connect them to the
terminals marked L1, L2, and
7. For pressure sensor leads, use the smaller
opening on the bottom of the SubDrive/
MonoDrive unit to the right of the input
power leads. Connect the red and
black leads to the terminals of the terminal block
on the Pressure Input Board marked "Pressure
Sensor" (interchangeable) with a small
screwdriver (provided). Torque the fitting as
shown in the figure to the right.
Note: The Pressure Input Board has two (2)
terminals labeled "AUX IN" that can be used to
provide an auxiliary control for the drive. This
connection is in series with the pressure sensor
input signal and is a non-powered connection.
The device connected to this terminal must be a
closed or shorted connection when it is desired
that the drive pump water (if the system pressure
is below the set point pressure of the pressure
sensor). If the "AUX IN" is an open circuit, the
drive will remain in idle mode regardless of
system pressure.
To use the "AUX IN" connections the break-away
tab on the lower-right corner of the Pressure Input
Board must be removed. If the break-away tab is
not removed, the "AUX IN" connections will always
be short circuited. If the break-away tab is removed
and the "AUX IN" terminals are not being used for an
auxiliary device, the "AUX IN" connections must then
be manually short circuited.
See figure to the right for location of this tab. The
Pressure Input Board should be removed from the
drive prior to prying off the break-away tab to prevent
damage to the drive.
28
.
Suitable for use on a circuit capable of
delivering not more than 5000 rms
symmetrical amperes, 250 V maximum.
Use 75 ºC CU wire rate 300 V min.
FAN
PRESSURE
Tighten terminals to 15 in-lbs.
SWITCH
OMRON
G68-2114P
-US
CONTACT:
5A 250VAC
12VDC
MADE IN
5A30VDC
CHINA
COIL:12VDC
OMRON
G68-2114P
CONTACT:
-US
5A 250VAC
12VDC
MADE IN
5A30VDC
CHINA
COIL:12VDC
L1
L2
COM NC NO
Installation/Operation manual may
be ordered by contacting your local
Franklin Electric representative.
Use 75 ºC CU wire rated 300 V min
Tighten terminals to 15 in-lbs.
RUN
RELAY
RED
YEL
BLK