Appliance Specifications; Electrical Connections - SCHOLTES BC 199D P 0 XA Manual De Instrucciones

Ocultar thumbs Ver también para BC 199D P 0 XA:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate (see table).
The appliance must be directly connected to the mains using an omnipolar
switch with a minimum contact opening of 3 mm installed between the
appliance and the mains. The switch must be suitable for the charge indicated
and must comply with current electrical regulations (the earthing wire must not
be interrupted by the switch). The supply cable must be positioned so that it
does not come into contact with temperatures higher than 50°C at any point
(the back panel of the oven, for example).
! The installer must ensure that the correct electrical connection has been
performed and that it is fully compliant with safety regulations.
Before connecting the appliance to the power supply, make sure that
• The appliance is earthed and the plug is compliant with the law.
• The socket can withstand the maximum power of the appliance, which is
indicated on the data plate.
• The voltage is in the range between the values indicated on the data plate.
• The socket is compatible with the plug of the appliance. If the socket is
incompatible with the plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power supply cable and the
electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures
not be observed.

APPLIANCE SPECIFICATIONS

width 43.5 cm
Dimensions*
height 41 cm
depth 41 cm
Volume*
74 l
width 45.6 cm
Dimensions**
height 41 cm
depth 41 cm
Volume**
77 l
voltage: 220-240V~ 50Hz
Electrical
maximum power absorbed 3400 W
connections
(see data plate)
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
ENERGY LABEL
implementing Directive 2009/125/EC.
and
Standard EN 60350-1
ECODESIGN
Standard EN 50564
Declared energy consumption
for Forced convection Class –
Gratin:
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 2004/108/EC of 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EU and subsequent
amendments.
- 1275/2008 standby/off mode.
* Only for models with drawn rails.
** Only for models with wire rails.
GB
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bc 199dt p 0 xaBcg 199d p 0Bcg 199d p 0 anBcg 199d p 0 miBcg 199d p 0 mtSch77 199dt p 0 ... Mostrar todo

Tabla de contenido