NOTE! If a message is displayed that is not shown in this user manual, see the PLC Settings
Manual for more information.
NOTE! If a warning or alarm is displayed that is not shown in this user manual, see the
PLC Settings Manual for more information and contact a Nederman authorized service
technician.
6.1

Status messages

The following status messages give information about what mode the unit is in or what
routine service is being performed.
6.1.1

Nederman FlexPAK Off (Off mode)

The unit is in Off mode, which is also the unit's start menu. The unit can also go into Off
mode if something is wrong, such as if an alarm is activated. The pump motor is off, there is
no vacuum, the FCV is closed, and the unit cannot be activated by a pilot signal.
FlexPak
Hi Vacuum Unit
OFF
Time To Service
2000 hours
ESC
OK
6.1.2

FlexPAK Standby (Standby mode)

The unit is in Standby mode. The pump motor is off, there is no vacuum, the FCV is closed,
and the unit is waiting for a pilot signal to go into Running mode.
NEDERMAN
FLEXPAK
Standby
Waiting For
Pilot Signal
Mo 15:33
ESC
OK
6.1.3

Running (Running mode)

The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
Running
kPA
-20
DIRTm
00:00 s
OTTmr
00:00 h
Exhaust
Air Temp
60°C
ESC
OK
6.1.4

FlexPAK Idling (Idling mode)

The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the time set in DIR_
Time.
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
ESC
OK
TimeToService: The amount of time until next scheduled service. The
default setting is 2000 hours.
DIRTm: The amount of time before the unit goes into Idling mode. The
default is 10 seconds.
OTTmr: If the Overtime timer has been activated, OTTmr shows the
elapsed time since the overtime timer started.
TimeToStandby: The amount of time until the unit goes into Standby
mode. The default setting is 12 minutes.
FlexPAK 800/1000 DX
EN
27