3.1
1) External fittings for doors
1
Moreover, external fittings for doors types following DIN 18273 with compliance
proof can be used.
2
2) Special keeps/electric release
3
Alternatively to the standard keeps the lock may also be furnished with special
keeps and electrical operating current door openers of the type series:
IST:
4
effeff:
DORMA:
without hold-open function.
5
When using electric release effeff 19, 116, 118, 119, 611 and IST A 7000 S each
classification scheme at the 4th position (proof of suitability for fire barriers) =
unsuitable enter a 0 zero.

3) Safety device

The panic locking system must be secured with the GfS-EH entry guard with inser-
tion part for panic bars.
Manufacturer: GfS Gesellschaft für Sicherungstechnik mbH
NOTE!
In fire protection doors, national regulations must be observed within the EU, if ap-
plicable. In addition, only electric releases suitable for fire protection may be used
in fire protection doors! The suitability of keeps for fire protection must be verified
in comparison with the available General Building Inspection Test Certificate (ABP
P-120002534) and the testing authority for the fire protection door.
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen
Subject to technical changes
Alternative facilities STV-AP 1125 und STV-BM EN 1125
FT 200, FT 201, FT500, FT 501, R 7000, R 7001, A 7000
142, 131, 111, 19, 116, 118, 119 and 611
Fire 447 and Smoke 117
Tempowerkring 15