WIRING DIAGRAM (VERSION WITH JACK)
The three-phase power supply line must have a switch with fuses.
The regulations further require a switch on the burner's power supply
line, outside the boiler room and in an easily accessed position. For
the electrical connections (line and thermostats), follow the wiring dia-
gram enclosed. To carry out the connection of the burner to the power
supply line proceed as follows:
1) In the case of models with mono-phase power supply insert the two
7 and 4 pole plugs in the sockets located below the electrical panel
base as shown in figure 1.
2) In the case of models with three-phase power supply, unscrew the
E
2 screws (1) and pull back lightly the cover to detach it from the electri-
cal panel base (see figure 2). Lift up the cover to reach the electrical
N
components.
G
3) Connect the power supply cables (2) to the contactor, fix the ground
L
cable (3) and tighten the cable holder (see figure 3). Connect the two
7 and 4 pole plugs.
I
4) Re-close the lid taking care to position the two hooks (4) correctly
S
in their right position (see figure 4).
H
Important: only qualified technicians may open the burner's electrical
panel.
Figure 1
32 / 89
0006081349_200802
Figure 2
Figure 3
Figure 4