General Installation Instructions - ABB M25102 K Serie Manual Del Usuario E Instrucciones

Ocultar thumbs Ver también para M25102 K Serie:
Tabla de contenido

Publicidad

ABB-Welcome
8.2

General installation instructions

Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
Do not install the wires of the system bus together with 100-240 V wires.
Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
Avoid bridges between different cable types.
Use only two wires for the system bus in a four-core or multi-core cable.
When looping, never install the incoming and outgoing bus inside the same cable.
Never install the internal and external bus inside the same cable.
The following installation situations must be avoided without fail:
Pos : 83 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ü r all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
|
-
Direct light
-
Direct sunlight
-
Extremely bright picture background
-
Highly reflective walls on the opposite side of the door station
-
Lamps or direct light sources
— 61 —

Publicidad

Tabla de contenido
loading

Tabla de contenido