Sammic SV Serie Instrucciones página 6

Envasadoras al vacío
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
CE Marking Indications
Each appliance is identified by the following
data:
• Manufacturer's name and address: SAMMIC,
S.L. Basarte, 1 Azkoitia Gipuzkoa (SPAIN).
• "CE" mark.
• The machine model as stated in the next
section.
• The serial number as indicated on the
guarantee slip and the Declaration of
Conformity.
MODELS
This manual describes the installation,
operation and maintenance of the sensor
controlled vacuum packing machines:
•tabletop models: SV-306S, SV-310S, SV-410S,
SV-420S, SV-520S
•free-standing models: SV-604S, SV-606S, SV-
806S, SV-810S
· Hinged hood models: SV-6100, SV-6160
The model reference and its specifications are
shown on the nameplate affixed to the
machine.
These vacuum packaging machines have been
designed and manufactured in accordance
with the following European directives:
89/392/EEC, 93/68/EEC, 73/23/EEC and to
the NSF Hygiene and Public Health standards.
INSTALLATION
For optimum performance and long service
life of the machine, follow the instructions
contained in this manual rigorously.
Location
Place the machine so that it stands perfectly
levelled. To avoid damages, never lean the
machine on one of its sides.
The tabletop machines must be installed on a
smooth surface, since their legs are made of a
sliding material for easy removal of the
machine in order to clean the support surface.
Electric connection
1. M
OTOR SPECIFICATIONS
-Single-phase motors are supplied for feeding
at 230V.
-Three-phase motors are suitable for 230V or
400V (connection to 400V).
Before connecting the vacuum packing
machine to the mains, check if the machine is
prepared for the same voltage as the mains.
To change the voltage (only three-phase
machines):
1.Connect the transformers to the suitable
voltage, as shown in the terminal strip.
2. If necessary, change the motor connections
as shown in the terminal box.
3. If necessary, adjust the temperature relay
as shown on the electric diagram.
2. C
ABLE SPECIFICATIONS
The SAMMIC vacuum packaging machines are
supplied with one thermoplastic-sheathed
cable 1.5m in length.
THEY MUST BE EARTHED. The grounding wire
6
EN
of the machine is identified. Furthermore, the
machine is fitted with an external screw for
the connection to an equipotential earthing
system.
- Three.phase machines: Prepare a wall-
mounted mains socket with 20 A, 3P+N+T
magneto-thermal and differential protection,
and a sealed plug to connect it to the power
supply cord of the packing machine.
- Single-phase machines: Prepare a wall-
mounted mains socket with 20 A, 2P+T
magneto-thermal and differential protection.
The plug which is part of the power supply
cord must be accessible.
For any repair work, the machine must be
disconnected from the grid, either by
disconnecting the magnetothermic switch, or
unplugging the connection.
3. T
O CHANGE THE VACUUM PUMP DIRECTION OF
(three-phase machines only):
ROTATION
If the vacuum pump motor generates unusual
noise on starting the machine, this means that
the motor rotates in the wrong direction. In
this event, immediately stop the machine and
invert two feed wires.
STARTING
In models SV-410S, SV-420S, SV-520S, SV-
600S, SV-800S and SV-6000 the pump already
contains oil.
In models
SV-310S fill the pump with oil
through the inlet, until oil reaches ¾ of the oil
sight. Detergent-free oils are to be used :
-SAE10 oil (detergent-free) for pumps with
outputs up to 20m³/h.
-SAE30 oil (detergent-free) for pumps with
outputs over 20m³/h.
Paraffin oils are recommended.
After pressing the general switch, it is
necessary to perform a few cycles on no load
before proceeding with the first packing, so
that the oil can heat up and provide the right
vacuum.
Sensor controlled vacuum %
This concerns the models in which all the
functions (programming, vacuum, gasflush
and
sealing)
are
controlled
microprocessor which uses a high-precision
sensor (0,2%), enabling a vacuum of up to
99,5% reliably and safely. It offers the
possibility of creating an additional time-
controlled vacuum.
Main features
-Fast and simple programming.
-Storage of 10 programmes.
-Automatic counter of the machine running
hours, with oil change warning signal.
-Automatic storage of the last executed
programme.
-Storage of programmes without a disposable
cell.
-LED-display of every stage executed within
the cycle.
-The "Stop- cycle switch" key interrupts the
function currently in operation and activates
the next function until the cycle is finished.
- VAC-NORM system. This permits the external
vacuum packaging of containers.
-Pump drying system. Recommended when
the pump is used to vacuum pack liquids, hot
cooked
products
environments.
Technical description of the control panel
When the operator switches on the main
switch of the machine, the display shows, for
two seconds, the number identifying the
machine configuration. Besides, it serves to
indicate
the
number
programme (from 0 to 9).
When the machine is switched on with the
main switch, a number representing the
number of hours the vacuum pump has been
operating, expressed in tens, is displayed for
2 seconds. If number 10 is displayed, it means
the pump has accumulated 100 hours of
operation. Afterwards, the vacuum, gas,
sealing time and other values can be displayed
by pressing the corresponding key.
Up - Dry-oil
- It serves to increase any of the values shown
in either display. Keep the key depressed to
reach the required value faster.
- After switching the machine on, two central
standby lines are displayed indicating that
no function has been selected (vacuum, gas
or sealing). Press this key for 3 seconds to
start the oil drying cycle (Dry oil).
by
a
Down
- It serves to decrease any of the values shown
in either display. Keep the key depressed to
reach the required value faster.
- After switching the machine on, two central
standby lines are displayed indicating that
no function has been selected (vacuum, gas
or sealing). Press this key for 3 seconds to
display the number of hours of operation.
Vacuum
This key is used to select the vacuum
percentage, from 0 to 99 %. The LED in this
key lights up when the vacuum percentage is
selected and during the vacuuming stage.
or
in
very
humid
Display 1
of
the
selected
Display 2

Publicidad

Tabla de contenido
loading

Tabla de contenido