• Installation clearances. Figure 1-26 gives the min.
installation space dimensions of the Ø 80/80
separator terminal kit in limited conditions.
• Extensions for the separator kit Ø 80/80. The
max. vertical straight length (without bends) that
can be used for Ø 80 intake and exhaust pipes is
41 metres of which 40 intake and 1 exhaust. The
total length corresponds to a resistance factor of
100. The total usable length obtained by adding
the length of the intake and exhaust pipes Ø 80
must not exceed the values stated in the following
table. If mixed accessories or components are
used (e.g. changing from a separator Ø 80/80 to
a concentric pipe), the maximum extension can
be calculated by using a resistance factor for each
component or the equivalent length. The sum of
these resistance factors must not exceed 100.
• Temperature loss in fume ducts. To prevent
problems of fume condensate in the exhaust pipe
Ø 80, due to fume cooling through the wall, the
length of the pipe must be limited to just 5 m.
Fig. 1-28). If longer distances must be covered,
use Ø 80 pipes with insulation (see insulated
separator kit Ø 80/80 chapter).
N.B.: when installing the Ø 80 ducts, a section
clamp with pin must be installed every 3 metres.
* The air intake pipe can be increased to 2.5 metres
if the exhaust bend is eliminated, 2 metres if the
air intake bend is eliminated, and 4.5 metres
eliminating both bends.
Használható maximális hosszúságok (beleértve a rácsos égéslevegőcső végelemet és a két, 90°-os könyököt)
Максимал ные испол зуемые длины (включая решётчатый вывод всасывания и два изгиба на 90°)
Lungimile maxime utilizabile (inclusiv terminalul de aspirare cu grilaj şi cele două curbe la 90°)
Maximálne použiteľné dĺžky (vrátane nasávacieho roštového koncového kusu a dvoch 90° kolien)
Max. използваема дължина (включително засмукващ решетест терминал и двете кривки на 90°)
HU
NEM SZIGETELT
ИЗОЛИРОВАННый
VEZETÉK
Füstgáz 1 m
Дымоудаление
Égéslevegő 36,0 m*
Всасывание
Füstgáz 2 m
Дымоудаление
Égéslevegő 34,5 m*
Всасывание
Füstgáz 3 m
Дымоудаление
Égéslevegő 33,0 m*
Всасывание
Füstgáz 4 m
Дымоудаление
Égéslevegő 32,0 m*
Всасывание
Füstgáz 5 m
Дымоудаление
Égéslevegő 30,5 m*
Всасывание
SZIGETELT
ИЗОЛИРОВАННый
VEZETÉK
Füstgáz 6 m
Дымоудаление
Égéslevegő 29,5 m*
Всасывание
Füstgáz 7 m
Дымоудаление
Égéslevegő 28,0 m*
Всасывание
Füstgáz 8 m
Дымоудаление
Égéslevegő 26,5 m*
Всасывание
Füstgáz 9 m
Дымоудаление
Égéslevegő 25,5 m*
Всасывание
Füstgáz 10 m
Дымоудаление
Égéslevegő 24,0 m*
Всасывание
Füstgáz 11 m
Дымоудаление
Égéslevegő 22,5 m*
Всасывание
Füstgáz 12 m
Дымоудаление
Égéslevegő 21,5 m*
Всасывание
• Inštalačné obvodové rozmery. Na obrázku
1-26 sú uvedené minimálne obvodové rozmery
inštalácie koncovej súpravy rozdeľovača o prie-
mere 80/80 v medzných podmienkach.
• Predlžovacie kusy pre deliaci súpravu o priemere
80/80. Maximálna lineárna dĺžka (bez záhybov)
vertikálne použiteľná pre nasávacie a výfukové
rúry o priemere 80 je 41 metrov, kde 40 je pre
nasávanie a 1 pre výfuk. Táto celková dĺžka
odpovedá odporovému faktoru o hodnote 100.
Celková užitočná dĺžka získaná súčtom nasáva-
cieho a výfukového potrubí o priemeru 80 môže
dosiahnuť maximálnych hodnôt uvedených v
tabuľke. V prípade nutnosti použitia doplnkov
alebo zmiešaných dielov (napríklad prechod z
rozdeľovača o priemere 80/80 na koncentrickú
rúru) je možné vypočítať maximálne možné
predlženie pomocou odporového faktoru pre
každý komponent alebo jeho ekvivalentnú
dĺžku. Súčet týchto odporových faktorov nesmie
prekročiť hodnotu 100.
• Strata teploty v dymovom potrubí. Aby ste sa
vyhli problémom s kondenzáciou spalín vo vý-
fukovom potrubí o priemere 80 spôsobeným ich
ochladením cez stenu, je nutné obmedziť dĺžku
bežného výfukového potrubia na 5 metrov (Obr.
1-28). Ak je potreba prekonať dlhšie vzdialenosti,
je nutné použiť izolované potrubie o priemere 80
(pozri kapitolu o izolovanej rozdeľovacej súprave
o priemere 80/80).
Poznámka: Pri inštalácii potrubia o priemere 80
je nutné každé tri metre inštalovať ťahový pás s
hmoždinkou.
* Nasávacie potrubie môže byť predlžené o 2,5
metru v prípade odstránenia kolena na strane
výfuku, 2 metre pri odstránení kolena na strane
odsávania a o 4,5 metrov v prípade odstránenia
obidvoch kolien.
Maximum usable length (including intake terminal with grill and two 90° bends)
RU
RO
НЕ
TUB NEIZOLAT
КАНАЛ
1 m
Evacuare 1 m
36,0 m*
Aspirare 36,0 m*
2 m
Evacuare 2 m
34,5 m*
Aspirare 34,5 m*
3 m
Evacuare 3 m
33,0 m*
Aspirare 33,0 m*
4 m
Evacuare 4 m
32,0 m*
Aspirare 32,0 m*
5 m
Evacuare 5 m
30,5 m*
Aspirare 30,5 m*
TUB IZOLAT
КАНАЛ
6 m
Evacuare 6 m
29,5 m*
Aspirare 29,5 m*
7 m
Evacuare 7 m
28,0 m*
Aspirare 28,0 m*
8 m
Evacuare 8 m
26,5 m*
Aspirare 26,5 m*
9 m
Evacuare 9 m
25,5 m*
Aspirare 25,5 m*
10 m
Evacuare 10 m
24,0 m*
Aspirare 24,0 m*
11 m
Evacuare 11 m
22,5 m*
Aspirare 22,5 m*
12 m
Evacuare 12 m
21,5 m*
Aspirare 21,5 m*
SK
• Пространство за инсталация. На фигура 1-26
са представени минималните инсталационни
разстояния за кита терминал сепаратор
Ø 80/80 при ограничени условия.
• Удължители за кит сепаратор Ø 80/80.
Максималната дължина по права линия (без
завои) вертикално, използваема за засмукваци
и отвеждащи тръби Ø80 е 41 метра, от които
40 за засмукване и 1 за отвеждане. Тази обща
дължина, отговаря на резистентен фактор
равен на 100. Общата използваема дължина,
получена сумирайки дължините на тръбите
Ø 80 за засмукване и отвеждане, може да
достигне като максимум стойностите приведени
в следната таблица. В случая, в който трябва
да се използват aксесоари или смесени части
(например преминаване от сепаратор Ø 80/80
към концентрична тръба), може да се изчисли
максимално достижимо удължение използвайки
един фактор на устойчивост за всеки компонент
или пък неговата еквивалентна дължина. .Сумата
от тези резистентни фактори не трябва да бъде
по-голяма от 100.
• Загуба на температура в отвеждащите тръби.
За да се избегне проблема с конденз на парите в
отвеждащите тръби Ø 80, дължащ се на тяхното
охлаждане при прминаване на стените, трябва да
се ограничи дължината на отвеждащата тръба
до 5 м. Ако трябва да се покриват по-големи
разстояния, е необходимо да се използват тръби
Ø 80 изолирани (виж глава кит сепаратор Ø 80/80
изолиран).
NB: при инсталиране на тръби Ø 80, трябва на всеки
3 метра да се инсталира захващаща скоба с тръпче.
* Засмукващата тръба може да се удължи до 2.5
m ако се премахне кривката за отвеждане, 2 m
ако се премахва засмукващата кривка или 4.5
m при премахване на двете кривки.
IE
NON INSULATED
NEIZOLOVANÉ
PIPE
Exhaust 1 m
Intake 36,0 m*
Nasávanie 36,0 m*
Exhaust 2 m
Intake 34,5 m*
Nasávanie 34,5 m*
Exhaust 3 m
Intake 33,0 m*
Nasávanie 33,0 m*
Exhaust 4 m
Intake 32,0 m*
Nasávanie 32,0 m*
Exhaust 5 m
Intake 30,5 m*
Nasávanie 30,5 m*
INSULATED
IZOLOVANÉ PO-
PIPE
Exhaust 6 m
Intake 29,5 m*
Nasávanie 29,5 m*
Exhaust 7 m
Intake 28,0 m*
Nasávanie 28,0 m*
Exhaust 8 m
Intake 26,5 m*
Nasávanie 26,5 m*
Exhaust 9 m
Intake 25,5 m*
Nasávanie 25,5 m*
Exhaust 10 m
Intake 24,0 m*
Nasávanie 24,0 m*
Exhaust 11 m
Intake 22,5 m*
Nasávanie 22,5 m*
Exhaust 12 m
Intake 21,5 m*
Nasávanie 21,5 m*
139
BG
SK
BK
НЕИЗОЛИРАН
POTRUBIE
ТРЪбОпРОВОД
Výfuk 1 m
Отвеждане
36,0 m*
Засмукване
Výfuk 2 m
Отвеждане
Засмукване
34,5 m*
Výfuk 3 m
Отвеждане
Засмукване
33,0 m*
Výfuk 4 m
Отвеждане
32,0 m*
Засмукване
Výfuk 5 m
Отвеждане
30,5 m*
Засмукване
ИЗОЛИРАН
TRUBIE
ТРЪбОпРОВОД
Výfuk 6 m
Отвеждане
29,5 m*
Засмукване
Výfuk 7 m
Отвеждане
28,0 m*
Засмукване
Výfuk 8 m
Отвеждане
26,5 m*
Засмукване
Výfuk 9 m
Отвеждане
25,5 m*
Засмукване
Výfuk 10 m
Отвеждане
24,0 m*
Засмукване
Výfuk 11 m
Отвеждане
22,5 m*
Засмукване
Výfuk 12 m
Отвеждане
21,5 m*
Засмукване
1 m
2 m
3 m
4 m
5 m
6 m
7 m
8 m
9 m
10 m
11 m
12 m

Publicidad