Installation Clearances with Flush Island Trim
36" (914 mm) min
to combustible
materials
36¾" (933 mm) Max.
35⅞" (911 mm) Min.
as defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
27⅝" (702 mm)
27¼" (692 mm)
24⅝" (625 mm)
24" (610 mm)
max. recess depth
24¾" (629 mm)
23" (584 mm)
44⅞" (1140 mm)
12" (305 mm) min. to
combustible surface
with Flush Island Trim
Cantilever
NOTE: If an inner
wall is used under
the cantilever counter
top, there should be a
⅛" (3 mm) gap from
the rear of the range
to the inner wall.
Figure 3: Installation Clearances with a Flush Island Trim
Combustible
Materials
NOTE: For Flush
Island Trim installations,
counter surface should
have a cantilever edge
meeting the back
section of the Flush
Island Trim accessory.