Installation Clearances

30" (762 mm) min from bottom of
Overhead Hood to Cooking
Surface
36" (914 mm) min if hood
contains combustible
materials
18" (457 mm)
minimum
*35 ⅞" (911 mm) Min. range height
with leveling legs fully retracted.
*36 ¾" (933 mm) Max. range height
with leveling legs fully extended.
*The range height is adjustable.
The level of the range top must
be at the same level or above
the counter top level.
{
30" or 36" (762 or 914 mm) Wide Hood
For 30" Ranges
36" or 42" (914 or 1067 mm) for Island
{
36" or 42" (914 or 1067 mm) Wide Hood
For 36" Ranges
42" or 48" (1067 or 1219 mm) for Island
{
48" or 54" (1219 or 1372 mm) Wide Hood
For 48" Ranges
54" (1372 mm) for Island
Min. Distance Between Overhead Cabinets
of Combustible Material
30" Range – 30" (762 mm)
36" Range – 36" (914 mm)
48" Range – 48" (1219 mm)
Range Width
30", 36", or 48"
(762, 914, or 1219 mm)
For Gas Supply & Electrical Zones see Figure 4.
Zone sizes & positions differ according to model.
13" (330 mm)
max. Cabinet
depth
5" (127 mm)
min. to combustible
sidewall material
(both sides)
as defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
m CAUTION!
(See Fig. 2 & Fig. 3)
36" (914 mm) min.
to combustible
material
from Cooking
Surface
Cooking
Surface
Figure 1: Cabinet Clearances
English 5