18 | VLS 3132 H | Symbols used
2.4.2

Construction of foundation

The foundation must be prepared in consultation
with the Bosch customer service agent or authorized
service outlets.
Individual footing:
Specifications
Min. length x width
Min. concrete thickness
Concrete quality B 4710-1
Surface
Upper and lower reinforcement
Fig. 3:
Individual footing
!
The base plates of the lifting platform must be
positioned centrally on the foundation.
Ground:
R
The ground must comply with the general guidelines
for foundations (Eurocode 7, formerly DIN 1054).
R
In the case of outdoor installation, the ground must
be frost-proof.
!
If the lifting platform is anchored to an existing
reinforced concrete floor, individual verification must
be provided by a structural engineer or building
expert!
!
Prior to installation, the condition of the concrete
and ground must be checked by means of a test
bore.
|
1 689 978 571
2011-06-01
Designation, value
2500 mm x 2000 mm
210 mm
C 20/25
Horizontal and even
(max. gradient: 0.5%)
BSt 500 M, Q131
2.4.3

Procurement of shear connectors

The shear connectors are not included in the scope of
delivery and must be provided by the user.
Recommended shear connectors:
Specifications
Qty.
Type
Anchor length
Min. substrate thickness
Min. bore hole depth
Embedment depth
Drill
Tightening torque
i
Shear connectors from other manufacturers may
be used, provided that they are approved by the
building authorities for use in the compression and
tension zone of the concrete. The fitting instructions
of the screw anchor manufacturer must be observed.
i
The shear connectors must penetrate the
subconcrete. The anchor length must be selected
in accordance with the floor structure over the
subconcrete:
Fig. 4:
Calculating the anchor length
L Anchor length
g
Visible thread length
t
Thickness of base plate of lifting platform column
s
Thickness of floor screed, including tiles
h Embedment depth (as specified by screw anchor manufacturer)
B Thickness of concrete (see section 2.4.2)
The embedment depth h and bore hole depth h+s
are specified by the screw anchor manufacturer. This
results in a minimum anchor length of L = h + s + t + g.
2.4.4

Laying electrical connections

Route the electrical wiring to the installation
location.
!
Fusing for the electrical connection must be
provided on site.
Designation, value
8 x (4 anchors per base plate)
Hilti HVA/HAS-M12x110
See Fig. 4
210 mm
110 mm
110 mm
Ø 14 mm
40 Nm