Preparing Maintenance Work - Dometic TEC29 Instrucciones De Uso

Ocultar thumbs Ver también para TEC29:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
TEC29, TEC29LPG
Interval
Inspection/maintenance
➤ Change the oil.
In the first
month or after
➤ Check the air filter ("Servicing the air filter (fig. 7, page 5)" on
20 hours.
➤ Check the air filter ("Servicing the air filter (fig. 7, page 5)" on
Every 3 months
or after
50 hours.
➤ Change the oil.
Every 6 months
or after
➤ Check the spark plug ("Servicing the spark plugs" on
100 hours.
➤ Check the valves.
Once a year or
every 300 hours
➤ TEC29 only: Check the fuel tank and fuel filter.
➤ Check the vibration damper.
Every two years ➤ TEC29 only: Check the petrol supply lines.
➤ TEC29LPG only: Check the gas supply lines.
10.2

Preparing maintenance work

CAUTION!
!
Note the following for all maintenance work:
 The generator must not be running.
 All the parts must be cooled down.
➤ Switch the generator to no function with the main switch (fig. 4 1,
page 4).
➤ Disconnect the positive terminal of the supply battery.
➤ Open the generator flap.
For maintenance work, you can take the generator out (fig. 5, page 4):
WARNING!
!
The mounting plate with generator is very heavy (> 40 kg) and
could fall out the housing if you take it out too far.
➤ Undo the fastening screws (1).
➤ Remove the mounting plate (2) with the generator from the housing (3).
EN
page 49).
page 49).
page 50).
Servicing the generator
47

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Tec29lpg

Tabla de contenido