The Status Displays - Multiplex ROYALevo 7 Manual De Instrucciones

Ocultar thumbs Ver también para ROYALevo 7:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ROYAL evo 7
10.7.

The status displays

In all, three different status displays are available, de-
signed to present relevant information while you are
flying. You can switch between the different status dis-
plays using the "L " or "M " buttons.
When you switch the transmitter on, the screen always
displays the status display you last used.
1
Status display
1
2
3
4
5
Bars
Line 1
Status of the 3D digi-adjustors.
Numerous set-up parameters can be assigned
to the 3D digi-adjustors; they can then be
fine-tuned directly while you are flying the
model (
11.2.2.).
Line 2
Current model memory showing
memory number (1): model name (BASIC)
Line 3
Actual operating voltage of the transmitter
battery in Volts, and as a graphic bar display
Line 4
Owner's name (
Line 5
Display of stopwatch time (
Bars
The four bars at the sides and bottom show
the current trim positions for the four primary
control functions / sticks (
2
Status display
(flight phases)
1
2
3
4
5
Bars
Line 1
Status of the 3D digi-adjustors; see above
Line 2
Current model memory; see above
Line 3
Actual operating voltage; see above
Line 4
Switch used to select the current flight phase
(
18.4.)
Line 5
Current flight phase (
- number of flight phase (example: "3")
- name of current flight phase
(example: "Thermal 1")
Bars
Current trim positions; see above
13.5.2.)
10.7.)
12.)
18.4.) showing:
Status display 3 (system information)
1
2
3
4
5
6
Line 1
- Transmitter type (ROYALevo 7)
- Software version (e.g. V1.28)
- Language set loaded
(e.g. DE/EN, German / English) (
Line 2
- No RF module
--> display: "No RF"
- Crystal RF module (HFM-4)
--> display: "HFM-4"
- Synthesizer RF module (HFM-S)
--> display: channel number and frequency
Line 3
Transmission mode, e.g. FM-PPM 6
according to servo assignment (
Line 4
Available residual battery charge (
Line 5
Available residual operating time
Calculated probable residual operating time,
based on momentary current drain and dis-
played battery charge (line 4). This is only dis-
played when the RF module is active, because
the very low currents when the RF module is
not active cannot be measured with sufficient
accuracy, and thus no accurate value can be
calculated (
Line 6
Transmitter's total operating time (operating
hours counter).
Re-starts at 0.0 h after reaching 999.9 h.
Page 20
13.5.1.)
16.2.)
8.5.)
8.5.)

Publicidad

Tabla de contenido
loading

Tabla de contenido