Engine Starting; Electric Starting; Remote Start - Mosa GE 4500 SX Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

ENGINE STARTING

Check Daily

ELECTRIC STARTING

NOTE
!
Do not alter the primary conditions of regulation and
do not touch the sealed parts.
1. Position the LOCAL START / REMOTE START (I6)
selector on LOCAL START;
2. make sure the load plugs are disconnected
or the G.F.I. switch (D) is not inserted (inter-
vention/insertion lever facing down), so as to
ensure the motor's start-up without any loads
inserted;
3. Open the gasoline tap (87) by turning it towards
the inside;
4. Turn the start-up key (Q1) to the ON position;
5. Move the CHOKE control to close and simultaneou-
sly turn the key to the START position, holding it until
the motor has started;
6. Leave the key in the ON position, then
wait a few moments before releasing the
choke control; if the motor tends to shut
itself off move the choke control once
again until the motor has properly started
up.
+ Do not use the CHOKE control if the motor is hot or
if the ambient temperature is suffi ciently high.
+ In case of unsuccessful start-up, do not insist
for longer than 5 seconds. Wait 10 seconds
before attempting another start-up.

REMOTE START

The unit can also be started by means of the remote
TCM control device, or through the EAS automatic
intervention panel.
1. Position the LOCAL START / REMOTE START (I6)
selector on REMOTE START;
2. Connect to the EAS (B3) connector the TCM or the
EAS panel.
Start-up with TCM
Use the controls located on the TCM in the same
manner as described for start-up from the front panel.
Start-up with EAS
The EAS panel will automatically manage the start-up.
See operating manual for EAS panel.
NB: it is necessary to unplug the EAS cable from its
Procedure to be followed also in case of emergency
start of electric start models.
1. Turn the fuel cock (87) to ON.
2. Switch the choke control (66) to CLOSE
FUEL COCK
3. Turn the engine switch (28) to the ON position
ENGINE SWITCH
4. Lightly pull the start-up knob (73) until meeting re-
sistance, then pull decisively.
 ATTENTION:
Allow the start-up knob to re-enter slowly, avoiding
having it knock against the motor and thereby da-
maging the start-up system.
5. Once the engine is started, with the starter off, let it
turn for a few minutes before drawing the load.
RUNNING-IN
During the fi rst 50 hours of operation, do not use more
than 60% of the maximum output power of the unit and
check the oil level frequently, in any case please stick
to the rules given in the engine use manual.
GE 4500 SX
GE 4500 SXE - EAS
GE 4500 SXE-AVR EAS
connector to allow the engine to start.
RECOIL STARTING
FUEL COCK
STARTER GRIP
CAUTION
!
M
26
REV.0-12/11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ge 4500 sxe-easGe 4500 sxe-avr eas

Tabla de contenido