4.2
Installation location requirements
WARNING
Aggressive atmospheres
Danger to personnel, system and environment can result from unsuitable environment.
Provide an environment suitable to the housing rating and materials of construction.
•
CAUTION
Direct sunlight
Device damage.
The device can overheat or materials become brittle due to UV exposure.
Protect the device from direct sunlight.
•
Make sure that the maximum permissible ambient temperature is not exceeded. Refer to the information in Chapter
•
"Technical data (Page 35)".
4.3
Proper mounting
4.3.1
Mounting location
Note
Correct location is key to a successful application.
•
Avoid reflective interference from vessel walls and obstructions by following guidelines in this chapter.
•
NOTICE
Incorrect mounting
The device can be damaged, destroyed, or its functionality impaired through improper mounting.
Before installing ensure there is no visible damage to the device.
•
Make sure that process connectors are clean, and suitable gaskets and glands are used.
•
Mount the device using suitable tools. Refer to the information in Installation instructions (Page 13) for installation
•
torque requirements.
Note
On devices with a removable head, there is no limit to the number of times a device can be rotated without damage.
•
When mounting, orient the front or back of the device towards the closest vessel wall or obstruction.
•
Do not rotate the enclosure after programming and vessel calibration, otherwise an error may occur, caused by a polarity
•
shift of the transmit pulse.
10
SITRANS LR250 (mA/HART)
A5E33469191-AA, 08/2014