6.2.5

Quick Start Wizard via the handheld programmer

Parameter menus
Note
For the complete list of parameters with instructions, and Dimension drawings, see the full operating instructions.
1. Quick Start
1.1. Quick Start Wiz
● Point the programmer at the display from a maximum distance of 300 mm (1 ft), then press RIGHT arrow
PROGRAM mode and open menu level 1.
● Press RIGHT arrow
● Press RIGHT arrow
● To change a setting, scroll to the desired item or key in a new value.
● After modifying a value, press RIGHT arrow
● Quick Start settings take effect only after you select Finish.
Material
Selects the appropriate echo processing algorithms for the material [see Position Detect (2.8.4.2.) for more detail].
Options
dK < 3.0
a)
Response Rate
Sets the reaction speed of the device to measurement changes in the target range. Use a setting just faster than the maximum
filling or emptying rate (whichever is greater).
Options
30
twice to navigate to menu item 1.1 and open parameter view.
to open Edit mode or DOWN arrow to accept default values and move directly to the next item.
to accept it and press DOWN arrow
*
LIQUID
LIQUID LOW DK
(low dielectric liquid – CLEF algorithm enabled)
a)
Response Rate (1.3.)
*
SLOW
MED
FAST
to move to the next item.
Fill rate per Minute (2.4.2.)/Empty rate per Minute
(2.4.3.)
0.1 m/min (0.32 ft/min)
1.0 m/min (3.28 ft/min)
10.0 m/min (32.8 ft/min)
to activate
SITRANS LR250 (mA/HART)
A5E33469191-AA, 08/2014