Checking The Seals Of The Ed12; If Malfunctions Occur - Aventics ED12 Instrucciones De Servicio

Ocultar thumbs Ver también para ED12:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Table 12:
Malfunction
No outlet pressure available No power supply
Outlet pressure too low
Outlet pressure less than
the set point
Outlet pressure does not
correspond to the stipulated
set point
AVENTICS | ED12 | R414002587–BDL–001–AB

10.2.1 Checking the seals of the ED12

The seals in the ED12 may age faster under aggressive ambient
conditions. Defective seals will lead to pneumatic leaks and non-
compliance with the IP 65 protection class.
Every now and then, check that the seals on the pressure
regulator are in perfect order.
A damaged seal can be recognized by parts of the seal visibly
protruding from the housing gaps.

11 If malfunctions occur

Possible cause
No set point stipulated
No supply pressure available
Supply pressure too low
Insufficient power supply for the
device
Consumers that use a lot of
air (> 2600 Nl/min) cause a large
drop in pressure in the device
Housing ventilation port is closed Ensure that the housing ventilation
Defective diaphragm in the
housing ventilation port
If malfunctions occur
Remedy
Connect the power supply
Check the polarization of the power
supply
Switch on system component
Stipulate a set point
Connect the supply pressure
Increase the supply pressure
Supply the device with correct
(sufficient) voltage
Reduce air consumption
port is open
Exchange the ED12
59

Publicidad

Tabla de contenido
loading

Tabla de contenido