Unit description

2. Unit description

2.1. Overview

The basic purpose of an inverter is to convert the direct current generated by the PV array into alternating current
to feed into the electricity grid.
The power structure of these inverters achieves a high performance with a flat curve, minimizing the cost and
weight of the inverter.
As standard the inverter includes communication via RS-485, an SD card reader for updating the firmware and
potential-free relay for signaling.

2.2. Optional accessories

These units may include the following accessories:
DC arresters.
Communications accessories.
Digital input card.
Self-consumption kit.
Combiner box.
DC arresters
Optionally, these units may incorporate two DC arresters, one per PV array.
Communication accessories
As standard these units have local communication via RS-485. In addition there is the option of establishing
connections using other technology types:
Ethernet (including communication via RS-485, for optional use).
Ethernet TCP (including communication via RS-485, for optional use).
GSM/GPRS (including communication via RS-485, for optional use).
Bluetooth.
Bluetooth (including communication via RS-485, for optional use).
Wi-Fi (including communication via RS-485, for optional use).
The instructions for installing the communications accessories are indicated throughout this manual. For more
information on their functioning, consult the corresponding communication accessories manual.
Digital input cards
In certain countries this card is necessary to comply with their regulations.
Self-consumption kit
These inverters are compatible with all the self-consumption options offered by Ingeteam.
Combiner box
Ingeteam has a combiner box, which is recommended for these inverters. Additionally, it is possible to use a
combiner box from an external manufacturer.
In the event of using a combiner box from an another manufacturer, the installer is responsible for
ensure that it complies with all the applicable legislation, and, particularly, necessary requirements
for operation together with a PV inverter in accordance with UL1741.

2.3. Electrical safety

The design values for electrical safety can be found below.
ABO2012IQM01_ - Installation and Operation Manual